INFORMATION
-
• This appliance is designed for wood firing so it cannot be applied for waste incineration or firing with liquid fuel, coal or their
derivatives.
• Observe the local and national regulations as well as the European standards during the installation and use of the appliance.
• Surface of the heating appliance is hot during the operation, especially the glazed front plate. It will have high temperature for a
long time even if no flame can already be seen in the combustion space. Be careful not to touch the hot surface of the appliance
(take special care of children)!
• Disconnect the voltage from all supplying circuits prior to obtaining access to the electrically connected devices.
• Install the appliance in accordance with the specifications of the effective standards. It is recommended to have the installation
performed by an expert.
• Observe strictly the instructions written in that guide. Keep these instructions carefully.
• Manufacturer’s responsibility covers only the delivered appliance and does not cover such cases when the responsibility results
from failing to observe the instructions.
Especially DO NOT:
- settle any material in the direct vicinity of the appliance which may be damaged or their consistence may be changed by heat
(e.g.: pieces of furniture, wall-paper, wooden furniture, etc.).
- install any heat recovering unit/system.
- use any fuel material other than natural wood or lignite.
- modify the appliance in any way not projected by the manufacturer; it will exclude manufacturer’s responsibility and result in the
withdrawal of guarantee. Use only the exchange parts recommended by the manufacturer!
• The person who performs the installation and setting bears full responsibility for failing to observe these instructions.
• Installation of the appliance in public places will be subject to the health regulations of the county which can be obtained from the
regional administrative authority.
• Manufacturer reserves the right to modify the appearance and dimensions of the models as well as the conception of fittings as
necessary without a previous notice.
- IMPORTANT INFORMATION ON THE INSTALLATION -
Your stove “pulls” well but you do not know the value of depression? The unit of depression or draught of the stove is Pascal (Pa).
All fireplace inserts, fireplaces and stoves are designed, optimized and manufactured in accordance with the standards EN 13240
(or EN 13229), with chimney connection of 12 Pa depression. In many cases (for each second chimney pull) the extent of draught
is too high (exceeds 20 Pa), which may result from the combination of too high chimney and installation with a flue pipe liner. In
such cases the appliances will operate under abnormal circumstances which may result in the following events:
- Too high wood consumption: it may increase to triple that of an appliance whose draught is 12 Pa.
- Fire which does not last: it burns too quickly and does not heat sufficiently.
- The appliance will damage quickly and permanently (cast iron plates or refractory bricks will crack).
- Guarantee will be withdrawn.
In order to avoid all these problems, there is only one solution: have your chimney draught inspected by an expert (with operating
appliance), and if it exceeds 20 Pa, have an automatic draught controller installed on the chimney connection.
1. TECHNICAL CHARACTERISTICS
STOVE
VALO
Type of stove
periodic
Nominal heat output (1)
10 kW
Operation
with closed door only
Liitoksen tyyppi
vertical
Average flue gas temperature
296 °C
Fume mass flow
6,4 g/s
Efficiency
80 %
CO-ration (13 % O
2
)
0,17 %
CO
2
–ration
13,1 %
Amount of particles
32 mg/Nm
3
Fuel materials
firewood or lignite
Size of sticks
max. 25 cm
Prohibited fuel materials
all other, including coal and derivatives
Nominal hourly consumption
3 kg
Refilling interval
1 h
Chimney pull nominal diameter
150 mm
Flue pipe characteristics
Flue pipe minimum dimensions
20 x 20 cm
The separate channel’s class T450 N1 D3 Gxxx (Ø mini)
150 mm
Minimum height of pipe above the appliance
4 m
Ventilation
1,2 dm²
Depression (10 Pa = 1 mm CE)
Nominal value of depression
12 Pa ± 2 Pa
Decreased value of depression (permissible minimum)
6 Pa
Permissible maximum
20 Pa
Net / gross weight
136/157 kg
Name-plate
on the back of appliance
Accessories
protective glove
(1) Nominal output while operating with closed door, wood or lignite firing; according to tests as per EN 13240.
(2) Contact your dealer.