The Advanced MCACC menu
10
74
En
Using Acoustic Calibration EQ Professional
1
Select ‘EQ Professional’, then press ENTER.
2
Select an option and press ENTER.
•
Reverb Measurement
– Use this to measu
r
e the
r
eve
r
b cha
r
acte
r
istics befo
r
e and afte
r
calib
r
ation.
•
Reverb View
– You can check the
r
eve
r
b
measu
r
ements made fo
r
s
p
ecified f
r
equency
r
anges
in each channel.
1
•
Advanced EQ Setup
– Use this to select the time
p
e
r
iod that will be used fo
r
f
r
equency adjustment and
calib
r
ation, based on the
r
eve
r
b measu
r
ement of
you
r
listening a
r
ea. Note that customizing system
calib
r
ation using this setu
p
will alte
r
the settings you
made in
Automatically conducting optimum sound
tuning (Auto MCACC)
on
p
age 35 o
r
Automatic
MCACC (Expert)
on
p
age 69 and is not necessa
r
y if
you’
r
e satisfied with these settings.
3
If you selected ‘Reverb Measurement’, select EQ
ON or OFF, and then START.
The following o
p
tions dete
r
mine how the
r
eve
r
b
cha
r
acte
r
istics of you
r
listening a
r
ea a
r
e dis
p
layed in
Reverb View
:
•
EQ OFF
– You will see the
r
eve
r
b cha
r
acte
r
istics of
you
r
listening a
r
ea
without
the equalization
p
e
r
fo
r
med by this
r
eceive
r
(befo
r
e calib
r
ation).
•
EQ ON
– You will see the
r
eve
r
b cha
r
acte
r
istics of
you
r
listening a
r
ea
with
the equalization
p
e
r
fo
r
med
by this
r
eceive
r
(afte
r
calib
r
ation).
2
Note that the EQ
r
es
p
onse may not a
pp
ea
r
enti
r
ely flat due to
adjustments necessa
r
y fo
r
you
r
listening a
r
ea.
3
When the
r
eve
r
b measu
r
ement is finished, you can select
Reverb View
to see the
r
esults on-sc
r
een. See
Professional Calibration EQ graphical output
on
p
age 89
fo
r
t
r
oubleshooting info
r
mation.
4
If you selected ‘Reverb View’, you can check the
reverb characteristics for each channel. Press RETURN
when you’re done.
The
r
eve
r
b cha
r
acte
r
istics a
r
e dis
p
layed when the
Full
Auto MCACC
o
r
Reverb Measurement
measu
r
ements
a
r
e conducted.
4
Use
/
to select the channel, f
r
equency and
calib
r
ation setting you want to check. Use
/
to go
back and fo
r
th between the th
r
ee. The
r
eve
r
b
cha
r
acte
r
istics g
r
a
p
h befo
r
e and afte
r
EQ calib
r
ation can
be dis
p
layed by selecting
Calibration : Before
/
After
.
Note that the ma
r
ke
r
s on the ve
r
tical axis indicate
decibels in 2 dB ste
p
s.
5
If ‘Advanced EQ Setup’ is selected, select the
MCACC memory to be stored, then enter the desired
time setting for calibration, and then select START.
5
Based on the
r
eve
r
b measu
r
ement above, you can
choose the time
p
e
r
iod that will be used fo
r
the final
f
r
equency adjustment and calib
r
ation. Even though you
can make this setting without
r
eve
r
b measu
r
ement, it is
best to use the measu
r
ement
r
esults as a
r
efe
r
ence fo
r
you
r
time setting. Fo
r
an o
p
timal system calib
r
ation
based on the di
r
ect sound coming f
r
om the s
p
eake
r
s, we
r
ecommend using the
30-50ms
setting.
Use
/
to select the setting. Use
/
to switch
between them.
Select the setting f
r
om the following time
p
e
r
iods (in
milliseconds):
0-20ms
,
10-30ms
,
20-40ms
,
30-50ms
,
40-
60ms
,
50-70ms
and
60-80ms
. This setting will be a
pp
lied
to all channels du
r
ing calib
r
ation.
When you’
r
e finished, select
START
. It will take about 2
to 4 minutes fo
r
the calib
r
ation to finish.
Afte
r
the Acoustic Calib
r
ation Equalization is set, you a
r
e
given the o
p
tion to check the settings on-sc
r
een.
Note
1 If the
Reverb View
pr
ocedu
r
e is
p
e
r
fo
r
med afte
r
the
Automatically conducting optimum sound tuning (Auto MCACC)
on
p
age 35 o
r
Reverb
Measurement
o
p
e
r
ation, de
p
ending on the standing wave cont
r
ol setting, diffe
r
ences may a
pp
ea
r
on the
r
eve
r
b g
r
a
p
h. With the Auto MCACC
function, the
r
eve
r
be
r
ations a
r
e measu
r
ed with the standing waves cont
r
olled, so the
r
eve
r
b cha
r
acte
r
istics g
r
a
p
h shows the cha
r
acte
r
istics
with the effect of the standing waves eliminated. By cont
r
ast, the
Reverb Measurement
function measu
r
es the
r
eve
r
be
r
ations without
cont
r
olling the standing waves, so the g
r
a
p
h indicates the
r
eve
r
b cha
r
acte
r
istics including the effect of the standing waves. If you wish to
check the
r
eve
r
b cha
r
acte
r
istics of the
r
oom itself (with the standing waves as such), we
r
ecommend using the
Reverb Measurement
function.
2 • The calib
r
ation co
rr
es
p
onding to the cu
rr
ently selected MCACC
pr
eset will be used when
EQ
ON
is selected. To use anothe
r
MCACC
pr
eset,
pr
ess
MCACC
to select the MCACC memo
r
y you want to sto
r
e.
• The
pr
edicted
r
eve
r
b cha
r
acte
r
istics afte
r
calib
r
ation can be acqui
r
ed with the
Full Auto MCACC
function (
Automatically conducting
optimum sound tuning (Auto MCACC)
on
p
age 35), but he
r
e the actually measu
r
ed
r
eve
r
b cha
r
acte
r
istics afte
r
calib
r
ation can be acqui
r
ed.
3 Afte
r
auto calib
r
ation with
EQ Type : SYMMETRY
(
Full Auto MCACC
, etc.), the g
r
a
p
h fo
r
the infe
rr
ed
r
eve
r
b cha
r
acte
r
istics can be dis
p
layed
by selecting
Reverb View
. To dis
p
lay the actually measu
r
ed
r
eve
r
b cha
r
acte
r
istics afte
r
EQ calib
r
ation, measu
r
e with
EQ
ON
.
4 The
After
dis
p
lay when measu
r
ements have been made using the
Full Auto MCACC
o
r
Auto MCACC
(
ALL
o
r
KEEP SP system
) function
shows the g
r
a
p
h fo
r
the infe
rr
ed
r
eve
r
b cha
r
acte
r
istics afte
r
EQ Type : SYMMETRY
calib
r
ation.
5 To s
p
ecify the
p
lace whe
r
e the MCACC memo
r
y is to be sto
r
ed,
pr
ess
MCACC
to select the MCACC memo
r
y you want to sto
r
e.
VSX-1120_UXJCB.book 74 ページ 2010年3月10日 水曜日 午後2時2分