PDP-505MX
92
1
2
3
4
1
2
3
4
C
D
F
A
B
E
Data Relay Board (LU)
Data Relay Board (CU)
Data Relay Board (RU)
Data Relay Board (RU)
CN8
CN1
CN8
CN3
CN3
OK: Open
NG: Short
Cause/Countermeasure:
2
If the connector CN8 disconnected from Data Relay Board (RU) is short-circuited between Pin 5 (or 6) and GND
(Pin 3 or 4)
⇒
Data IC is broken
⇒
Exchange PDP.
3
If the connector CN8 disconnected from Data Relay Board (RU) is short-circuited between Pin 1 (or 2) and GND
(Pin 3 or 4)
⇒
Data Relay Board (RU) is failed
⇒
Exchange Data Relay Board (RU).
4
If the connector CN1 disconnected from Data Relay Board (CU) is short-circuited between Pin 5 (or 6) and GND
(Pin 3 or 4)
⇒
Data IC is broken
⇒
Exchange PDP.
5
If the connector CN1 disconnected from Data Relay Board (CU) is short-circuited between Pin 1 (or 2) and GND
(Pin 3 or 4)
⇒
Data Relay Board (LU) or (CU) is failed
⇒
a) If the connector CN3 disconnected from Data Relay Board (LU) is short-circuited between Pin 2 and GND (Pin 3 or 4)
⇒
Data Relay Board (LU) is failed
⇒
Exchange Data Relay Board (LU).
b) If the connector CN3 disconnected from Data Relay Board (CU) is short-circuited between Pin 2 and GND (Pin 3 or 4)
⇒
Data Relay Board (CU) is failed
⇒
Exchange Data Relay Board (CU).
Data Relay Board(LD)
Data Relay Board(CD)
Data Relay Board(RD)
Data Relay Board(RD)
CN8
CN1
CN8
CN3
CN3
OK: Open
NG: Short
Cause/Countermeasure:
6
If the connector CN8 disconnected from Data Relay Board (RD) is short-circuited between Pin 5 (or 6) and GND
(Pin 3 or 4)
⇒
Data IC is broken
⇒
Exchange PDP.
7
If the connector CN8 disconnected from Data Relay Board (RD) is short-circuited between Pin 1 (or 2) and GND
(Pin 3 or 4)
⇒
Data Relay Board (RD) is failed
⇒
Exchange Data Relay Board (RD).
8
If the connector CN1 disconnected from Data Relay Board (CD) is short-circuited between Pin 5 (or 6) and GND
(Pin 3 or 4)
⇒
Data IC is broken
⇒
Exchange PDP.
9
If the connector CN1 disconnected from Data Relay Board (CD) is short-circuited between Pin 1 (or 2) and GND
(Pin 3 or 4)
⇒
Data Relay Board (LD) or (CD) is failed
⇒
a) If the connector CN3 disconnected from Data Relay Board (LD) is short-circuited between Pin 5 and GND (Pin 3 or 4)
⇒
Data Relay Board (LD) is failed
⇒
Exchange Data Relay Board (LD).
b) If the connector CN3 disconnected from Data Relay Board (CD) is short-circuited between Pin 5 and GND (Pin 3 or 4)
⇒
Data Relay Board (CD) is failed
⇒
Exchange Data Relay Board (CD).
Summary of Contents for PDP-505MX
Page 7: ...PDP 505MX 7 5 6 7 8 5 6 7 8 C D F A B E ...
Page 21: ...PDP 505MX 21 5 6 7 8 5 6 7 8 C D F A B E ...
Page 46: ...PDP 505MX 46 1 2 3 4 1 2 3 4 C D F A B E Sensor Board IR Board Power Switch Board ...