PDP-504CMX/1
102
1
2
3
4
1
2
3
4
C
D
F
A
B
E
Adjustment of corresponding route unevenness
Basically, only replacement of service parts is required, and adjustment is not required.
No.
Command
Adjustment
Parameter Name
in Factory
Function
1
VSG
CVY GAIN
2
VSO
CVY OFFSET
3
RYG
RY GAIN
4
GYG
GY GAIN
AD G GAIN adjustment (correction in differences between component- and RGB-system signals)
AD R GAIN adjustment (correction in differences between component- and RGB-system signals)
IC1 MAIN OFFSET adjustment (switching routes with the SWM [main] and SWS [sub]
commands)
IC1 MAIN GAIN adjustment (switching routes with the SWM [main] and SWS [sub]
commands)
5
BYG
BY GAIN
AD B GAIN adjustment (correction in differences between component- and RGB-system signals)
6
ADC
AD MAIN GAIN
AD MAIN RGB GAIN adjustment (for main screen)
7
MRG
AD MAIN RY GAIN
AD MAIN RY GAIN adjustment (for main screen)
8
MGG
AD MAIN GY GAIN
AD MAIN GY GAIN adjustment (for main screen)
9
MBG
AD MAIN BY GAIN
AD MAIN BY GAIN adjustment (for main screen)
10
MRO
AD MAIN RY OFS
AD MAIN RY OFFSET adjustment (for main screen)
11
MGO
AD MAIN GY OFS
AD MAIN GY OFFSET adjustment (for main screen)
12
MBO
AD MAIN BY OFS
AD MAIN BY OFFSET adjustment (for main screen)
13
SRG
AD SUB RY GAIN
AD SUB RY GAIN adjustment (for sub screen)
14
SGG
AD SUB GY GAIN
AD SUB GY GAIN adjustment (for sub screen)
15
SBG
AD SUB BY GAIN
AD SUB BY GAIN adjustment (for sub screen)
16
SRO
AD SUB RY OFS
AD SUB RY OFFSET adjustment (for sub screen)
17
SGO
AD SUB GY OFS
AD SUB GY OFFSET adjustment (for sub screen)
18
SBO
AD SUB BY OFS
AD SUB BY OFFSET adjustment (for sub screen)