8.3 HOW TO CLEAR HISTORY DATA
Clearance of various logs after the Assys are replaced
Besides adjustment data, data on accumulated power-on time and logs on defective parts of the product are backed up.
Some of those data must be cleared after the Assys are replaced for service.
Clearance of those data can be performed in the ETC layer of the Factory menu or with RS232C commands.
Notes: •
As the pulse-meter count is used for each correction function, the log must be cleared when the panel is replaced.
•
After you clear the log, the unit must be turned off then back on again to reflect the cleared data for each correction
function. If any adjustment is required after clearing the log, be sure to turn the unit off then back on again before
adjustment.
(1) Clearance of logs, using the Factory menu
1
Turn on the power.
2
Enter the Panel Factory mode.
3
Clear the various logs, as shown in the figure below.
Note:
The following example shows how to clear the PD log (PD INFO.). To clear other items, select each item you wish to
clear then perform the same procedures.
4
Turn off the power.
PANEL INFORMATION
ETC. (+)
BACKUP DATA : NO OPRT
BACKUP DATA : NO OPRT
DIGITAL EEPROM : NO OPRT
PD INFO. < = > : NO OPRT
PD INFO. < = > : CLEAR
Key Down 7th
Key Down
SET
Right
SET (5 sec)
Key Down
Key Down
Item
Content
Panel
Clearing at the Replacement
Clearing method
POWER SUPPLY
Unit
Other parts
RS-232C
Commands
Hour-meter
Accumulated power-on time
Must be cleared
No need to be
cleared
No need to be
cleared
CHM
Pulse-meter
Accumulated number of pulses emitted
Must be cleared
(mandatory)
No need to be
cleared
No need to be
cleared
CPM
Shutdown history
of the panel
Causes and hour-meter values for the
last eight shutdowns (SD) of the Panel
Must be cleared
No need to be
cleared
No need to be
cleared
CSD
Power-down history
Causes and hour-meter values for the last
eight power-downs (PDs) of the Panel
Must be cleared
No need to be
cleared
No need to be
cleared
CPD
Power-on counter
Relay-on count
No need to be
cleared
Must be cleared
(mandatory)
No need to be
cleared
CPC
MAX TEMP
Historical max. temperature of the
panel
Must be cleared
Must be cleared
Must be cleared
CMT
Factory Menu
(ETC layer)
HR-MTR INFO.
PM/B1-B5
SD INFO.
PD INFO.
P COUNT INFO.
MAX TEMP.
(2) Using the RS-232C commands
1
Turn on the power.
2
Issue the FAY command.
3
Issue the Delete command for a log you wish to clear.
4
Turn off the power.
Summary of Contents for Kuro Elite PRO-141FD
Page 10: ...10 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 2 2 SPECIFICATIONS PRO 141FD KU CBXC ...
Page 11: ...11 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F KRP 600M KUCXC ...
Page 12: ...12 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 KRP 600M YVPSLFTD TYVXK5 ...
Page 13: ...13 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F 2 3 PANEL FACILITIES For PRO 141FD ...
Page 14: ...14 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 Front Section for KRP 600M ...
Page 15: ...15 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F Rear Section for KRP 600M ...
Page 16: ...16 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 Remote Control Unit ...
Page 17: ...17 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 22: ...22 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Page 24: ...24 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 4 2 OVERALL WIRING DIAGRAM 2 2 ...
Page 25: ...25 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F OVERALL DIAGRAM PRO 141FD KRP 600M ...
Page 37: ...37 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 43: ...43 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 73: ...73 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 209: ...209 PRO 141FD 5 6 7 8 5 6 7 8 A B C D E F ...
Page 212: ...212 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 9 2 PACKING SECTION KRP 600M KUCXC 4 Cable clamps ...
Page 226: ...226 PRO 141FD 1 2 3 4 A B C D E F 1 2 3 4 9 9 PANEL CHASSIS SECTION ...