background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING, CONNECTED 

TO A POWER SOURCE, OR WHILE CONNECTED TO A FUEL SOURCE.

© 2019 Pinnacle Climate Technologies, Inc. 

Cabinet Heater User's Manual

11

STORAGE / MAINTENANCE

Always disconnect the LP cylinder from the regu-

lator assembly and remove the LP cylinder from 

the heater before putting the heater into storage. 

If, for any reason, the heater is to be stored in-

doors, the heater MUST be disconnected from the 

LP cylinder, and the cylinder stored outdoors in a 

well-ventilated area, out of the reach of children, 

and in accordance with the Standard for Storage 

and Handling of Liquefied Gasses, ANSI/NFPA 58 

and Natural Gas and Propane Installation Code, 

CSA B149.1- latest edition. The plastic valve plug 

or valve cover supplied with the LP cylinder must 

be reinstalled on the valve to protect the fitting 

from damage.

NOTE: Repair of this heater should be done by a 

qualified service person.

It is recommended that you save all of the pack-

aging materials that came with your heater, and 

re-package the heater using these materials for 

safe storage.

Debris, dust and dirt inside of the heater body 

can affect the performance of your heater. This 

debris can impair the heaters ability to draw air for 

ventilation and combustion. Spiderwebs can also 

appear during periods of inactivity.

Be sure to inspect the heater before each use to 

look for any such obstructions. Be sure to keep 

the air passage-ways, burner and combustion 

areas clean. Wipe with a damp cloth or use a 

vacuum cleaner to clean these areas. It is sug-

gested that you perform a thorough cleaning at 

least once every 30 days of operation. You may 

need to clean the heater more often if conditions 

are naturally dirty. Clean the heater, including spe-

cial surfaces, with recommended cleaning agents, 

if necessary.

Clean the ceramic plaques using compressed air 

below 30 PSI to prevent damage to plaques.

A yellow tip of the pilot flame indicates that the 

burner area may be in need of cleaning.

Never store an LP cylinder inside of a building or near any other gas or 

oil burning appliances.

DANGER

Always be sure that the heater has been allowed to cool for at least 30 

minutes before attempting to store, service, or perform maintenance.

CAUTION

Summary of Contents for REMINGTON REM-18PNCH-B

Page 1: ...OLINE SOLVENTS PAINT THINNERS DUST PARTICLES OR UNKNOWN CHEMICALS KEEP ALL COMBUSTIBLE MATERIALS GASOLINE AND OTHER FLAM MABLE VAPORS AND LIQUID AWAY FROM THIS HEATER This heater is designed and appro...

Page 2: ...can expose you to chemicals including lead which is known to the State of California to cause cancer and birth defects or other reproductive harm For more information go to www P65Warnings ca gov EXT...

Page 3: ...high altitudes FOR INDOOR USE ONLY Adequate ventilation shall be provided in accordance with OSHA 29 CFR 1926 154 Safety Requirements for Temporary and Portable Space Heating Devices and Equipment ANS...

Page 4: ...pane Installation Codes CSA B149 1 Periodically monitor levels of CO CO and NO existing at the construction site at the minimum at the start of the shift and after 4 hours Provide ventilation air exch...

Page 5: ...any other gas Installation must conform to local codes or in their absence with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and the Natural Gas and Propane Inst...

Page 6: ...t connector and hose regulator assembly for storage 2 Remove all items from carton 3 Check all items for shipping damage If the heater is damaged promptly inform dealer where you purchased the heater...

Page 7: ...e bottom plate and replace the back cover 2 To connect LP cylinder insert regulator end fitting into cylinder valve rotate coupling nut clockwise and tighten firmly see Figure 2 3 Open valve on propan...

Page 8: ...ipping the LP cylinder on its side when connected to a regulator since this may cause damage to diaphragm in the regulator Handle valves with care Never connect an unregulated LP cylinder to a constru...

Page 9: ...on Keep gasoline and any other flammable liquids away from the heater WARNING Lighting Instructions 1 STOP Read all of the safety information provided with this heater 2 Turn valve on propane cylinder...

Page 10: ...To move the heater release the brakes simply by flipping the levers on both brakes up The gas must be turned off at the propane supply cylinders s when the heater is not in use OPERATION CONT Risk of...

Page 11: ...nd re package the heater using these materials for safe storage Debris dust and dirt inside of the heater body can affect the performance of your heater This debris can impair the heaters ability to d...

Page 12: ...der valve Wait 1 min for switch to click off Reopen LP cylinder valve slowly 7 Move heater to a level surface No spark created when ignited 1 Incorrect igniter electrode position 2 Electrode damaged o...

Page 13: ...012 0260 No Part 1 Switch 2 Piezo Ignition 3 Switch Base 4 Top Nut 5 Valve 6 Burner 7 3rd Setting Copper Pipe System 8 1st Setting Copper Pipe System 9 ODS Copper Pipe 10 2nd Setting Copper Pipe Syst...

Page 14: ...he item freight pre paid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in...

Page 15: ...Sauk Rapids MN 56379 USA Toll Free 800 641 6996 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2019 Pinnacle Climate Technologies Inc...

Page 16: ...S VOLATILES OU EN SUSPENSION DANS L AIR OU ENCORE DES PRODUITS COMME DE L ESSENCE DES SOLVANTS DES DILUANTS PEINTURE DES PARTICULES DE POUSSI RE OU DES PRODUITS CHIMIQUES INCONNUS GARDER TOUS LES MAT...

Page 17: ...te chaufferette AVERTISSEMENT CET APPAREIL EST EXTR MEMENT CHAUD PENDANT SON FONCTIONNEMENT Ne toucher aucun composant en m tal pendant le fonctionnement Garder tous les mat riaux combustibles l essen...

Page 18: ...GE INT RIEUR SEULEMENT Fournir une ventilation ad quate conform ment la norme OSHA 29 CFR 1926 154 aux exigences de s curit pour les appareils et quipements portables de chauffage temporaire la norme...

Page 19: ...s sur le chantier au minimum au d but du quart de travail et apr s 4 heures Assurer un change d air par une ventilation appropri e naturelle ou m canique afin de maintenir une qualit acceptable de l a...

Page 20: ...absence avec la norme du Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 et du Code d installation du propane et du gaz naturel CSA B149 1 V rifier les connexions d alimentation en gaz...

Page 21: ...e et tuyau r gulateur pour l entreposage 2 Enlever tous les articles du carton 3 V rifier qu aucun article n a t endommag pendant le transport Si la chaufferette est endommag e informer imm diatement...

Page 22: ...capot arri re 2 Raccorder la bouteille de propane ins rer le raccord du r gulateur dans le robinet de la bouteille tourner l crou du raccord dans le sens horaire et le serrer fermement Figure 2 3 Ouvr...

Page 23: ...e d endommager le diaphragme l int rieur du r gulateur Manipuler les robinets avec pr caution Ne jamais raccorder une bouteille de propane sans r gulateur une chaufferette de construction NE PAS soume...

Page 24: ...tre liquide inflammable loin de la chaufferette Instructions d allumage 1 ARR TER Lire toutes les informations sur la s curit fournies avec cette chaufferette 2 Tourner le robinet de la bouteille de p...

Page 25: ...Pour d placer la chaufferette rel cher les freins en relevant simplement le levier des deux roulettes Le gaz doit tre coup au niveau du ou des cylindres d alimentation en propane lorsque la chauffere...

Page 26: ...t s r Les d bris la poussi re et les salet s l int rieur du bo tier de la chaufferette peuvent nuire son rendement De tels d bris peuvent r duire la capacit de l appareil aspirer de l air pour la vent...

Page 27: ...la bouteille de GPL Attendre une minute que l interrupteur s ouvre Rouvrir le robinet de la bouteille 7 Replacer l appareil sur une surface plane Aucune tincelle produite lors de l allumage 1 Positio...

Page 28: ...crou sup rieur 5 Robinet 6 Br leur 7 Syst me de tuyauterie en cuivre troisi me position 8 Syst me de tuyauterie en cuivre premi re position 9 Tuyau de cuivre du capteur d appauvrissement en oxyg ne 10...

Page 29: ...ion et d terminera s il est d fectueux Pinnacle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technologies Inc d termine que l article est dan...

Page 30: ...Sauk Rapids MN 56379 USA Num ro sans frais 800 641 6996 T l copieur 320 251 2922 Web www remingtonheater com Courriel info pinnacleclimate com 2019 Pinnacle Climate Technologies Inc...

Reviews: