Programming the RC-U
22
SuperVsn
is the interval (in hours) that the control panel is expecting to receive a
supervision signal from each of the wireless detectors. If a signal is not received
within this time frame, a failure shall be recorded in the system’s history log
(memory) and a System Response is issued (as programmed in Response to Zone
Failure - see the HUNTER-PRO installation manual).
NOTE:
As wireless PIR transmit supervision signal approximately every 3 hours, the
programmed interval should be more then 3 hours.
Setting 0 (zero) as the supervision interval shall disables this feature.
NOTE:
When the supervision interval is set to anything but 0 (zero), all “empty zones” (i.e.,
zones which are not linked to wireless devices) must be permanently bypassed in the
zone characteristic programming. Failing to do so will cause a Supervision Lost
indication and reporting.
g
Example1:
Installing 8 wired zones with 8 wireless zones. Zones 9,10,11,12 and 13 are linked to
wireless detectors. Zones 14, 15, and 16 are left unlinked and thus must be bypassed.
g
Example2:
Installing 16 wireless zones. Zones 1 to 12 are linked to wireless detectors. Zones 13 to 16
are left unlinked and thus must be bypassed.