background image

 

26 

HUNTER-PRO Series & CAPTAIN 8 User Guide 

 

 

11

 

THE CHIME FEATURE (KEY #) 

 

 User code 

 

 

Zone  Number :   1
ENTR- Conf   #- Rs t

 

 zone number :

 

 to assign the chime to the zone    

-OR-

 

 to cancel a zone assignment 

 

The chime helps supervising the opening of doors and windows by sounding a series of 
beeps, anytime one of them is opened. 

 

This feature is especially useful with small children in the house and in shops. 

 

The chime is active only when the system is disarmed.

 

 

The letter “C” in the “Fast zone” display type indicates the chime is assigned to that zone. 

11.1

 

Enabling and disabling the Chime globally 

 

Pressing the 

 key for 2 seconds enables and disables (toggle mode) the chime globally, 

to all the chime zones. 

 

A verification message, “Chime ON”/“Chime OFF”, is displayed. 

12

 

OTHER TOPICS 

12.1

 

Partitions 

 

A partition (or sub-system) is a logic or physical area, made of several zones, e.g., a 
separate compound, a house floor, an office, a perimeter zone. 

 

A partition can be armed, while others (i.e., other zones) are not. In this way, only those 
zones that are allocated to the armed partition/s will activate the alarm, when they are 
opened; zones outside the armed partitions can be occupied at the same time.  

 

Partitions are programmed by the Installer. 

 

There can be up to 16 partitions in Hunter-Pro Series and 4 in Captain 8. 

 

Monitored keypads can also be assigned per partition.  

 

Users can also be allocated to partitions, i.e., control (e.g., arm & disarm) only some of 
the zones. 

ENTR

ENTR

ENTR

ENTR

#

#

#

#

Summary of Contents for Captain 8

Page 1: ...Hunter Pro 832 896 8144 Captain 8 S e c u r i t y S y s t e m s User Guide...

Page 2: ...e and date Set the user codes Set the chime per zone Turn ON Off the chime feature in chime zones Set auto arming by day and inactivity Reset smoke detectors Press briefly display armed partitions Sil...

Page 3: ...arming 12 4 2 Prior to arming 12 5 HOME 1 HOME 2 ARMING MODES KEYS 4 7 13 6 DISPLAYING TYPES KEY 5 14 6 1 Fast 32 zone display 14 6 2 Scan open zones 15 6 3 Disable zone displaying 16 6 4 Other displa...

Page 4: ...isplaying armed partitions 30 12 2 Arming with key key fob or RFID tag key chain 30 12 2 1 Arming with a key fob 30 12 3 Enabling Remote Upload 31 12 4 Names and Characters 31 12 4 1 Example 32 12 5 P...

Page 5: ...odes full or partial HOME 1 HOME 2 Equipped with menu driven LCD and Graphic keypads and cost effective LED keypads Optional use of partitions for perimeter zones and separate locations Various automa...

Page 6: ...side it Refer servicing to qualified personnel only This alarm system should be used with 230VAC 50Hz protected by anti electric shock breaker To prevent electric shocks and fire hazards do NOT use an...

Page 7: ...distress situations Entering the code disarms the system when armed and generates a silent alarm to the Monitoring Station if one is a subscriber and to your phone The code is a 4 6 digit code 1 7 The...

Page 8: ...ing Key fob key switch and RFID tag keychain 4 In Hunter Pro only by a remote control and via the phone As a rule arming should be carried out only when all the zones are closed but those on the exit...

Page 9: ...rming until the Exit delay starts OR Short code Fast single keystroke arming must be enabled by the Installer To set the Short code see section 9 12 2 2 Disarming User code To disarm the system enter...

Page 10: ...per line a serial number and the date time stamp when the entry i e the event was logged the event details appear on the bottom line The log has 4 list sorting options All the events which displays al...

Page 11: ...ected 4 1 When arming User code to temporarily bypass the open zone s OR to cancel arming When you try to arm the system and a 24 hour zone2 is open the keypad sounds beeps and the message Open Zone P...

Page 12: ...zones are armed while others are not while the armed zones sound the alarm if violated the disarmed zones can be occupied at the same time Common applications for the Home modes are perimeter detecto...

Page 13: ...various information for a minute before they return to one of the basic types Zone names are programmed by the Installer 6 1 Fast 32 zone display User code Di s pl ay Ty pe Fas t Zn Di s pl ay This di...

Page 14: ...splayed intermittently A Alarmed zone the zone was violated when the system was armed or is alarming now B Bypassed zone C Chime zone F Zone failure disconnection or a TAMPER switch is open L Low batt...

Page 15: ...code X3 zone number repeatedly The properties of every programmed zone name partitions and type are displayed when pressing repeatedly 6 4 2 Bypassed Zones User code X4 to display other bypassed zone...

Page 16: ...display the status of all the programmed zones quickly It is design the same as the Fast zone type 10 zones in each line and 20 in every screen See section 6 1 for details on the signs In the above sc...

Page 17: ...s User code phone 1 or The HUNTER PRO Series the Captain 8 have an integrated phone dialer that can call up to 4 numbers and sound an alarm or send SMS alert or sound a recorded message When an alarm...

Page 18: ...receive SMS messages will not receive the siren alarm For example phone 2 will receive SMS messages Sending SMS messages requires the purchasing of the SMS 100 module or the GSM 200 cellular module 7...

Page 19: ...d and the keypad beeps 9 CODES KEY 9 Codes in the Hunter Pro Series and Captain 8 systems are made of 4 6 digits except for the Short code Duplicate codes or codes that start with same two digits as t...

Page 20: ...ser number Del et e Code ENTER NEXT END Once a code is deleted the asterisk is deleted too and the code is available to be used for another user 9 3 User name User code user number X2 User Nam e ENTER...

Page 21: ...Authorized to set change the auto arming time O OP CL Report SMS Authorized to receive SMS reports anytime the system is armed and disarmed R Remote control In Hunter Pro Series only authorized to co...

Page 22: ...ssigned to the partitions its assigned to see parameter K in the User Settings section 9 4 9 7 Adding a key fob User code user number X6 Add k ey f ob ENTER NEXT END Add k ey f ob Ac t i v at e dev i...

Page 23: ...n 9 4 9 10 Deleting RFID Tag User code user number X9 9 9 9 9 CODES NEXT NEXT NEXT NEXT Us e r Co d e s ENTER NEXT END ENTR ENTR ENTR ENTR ENTR ENTR ENTR ENTR NEXT NEXT NEXT NEXT ENTR ENTR ENTR ENTR D...

Page 24: ...RELAY 10 AUTOMATIC ARMING KEY 9 The Hunter Pro Series Captain 8 systems offer two ways to arm the system to full mode automatically by day and hour or by lack of activity Automatic arming can be used...

Page 25: ...rmed This feature can help you ensure that the premises will always be armed when it is no longer occupied e g during the night This feature can be set per partition so some partitions can be armed au...

Page 26: ...ables toggle mode the chime globally to all the chime zones A verification message Chime ON Chime OFF is displayed 12 OTHER TOPICS 12 1 Partitions A partition or sub system is a logic or physical area...

Page 27: ...is divided into partitions each controlled by a separate keypad The users have authorization levels based on partition s e g user 12 can only control Partition 3 14 Every keypad displays the status o...

Page 28: ...and displays partition 3 only Example D office compound Figure 5 Implementing partitions Example D A compound is made of 16 offices each is located in a separate room Each room is assigned as a parti...

Page 29: ...key fob or RFID tag keychain You can arm your system using key switch key fob and RFID tag keychain The three accessories are assigned per user A key switch requires no other module and is used mostly...

Page 30: ...only the Master code can enable it and press twice 12 4 Names and Characters Names and characters are entered the same way as in cell phones each key has letters and characters associated with it A Us...

Page 31: ...r and your phones In addition to activating the sirens the Installer can set the system to response in various ways 12 6 Resetting Smoke Fire Anti mask detectors Smoke Fire and Anti mask detectors nee...

Page 32: ...Zones 8 basic 32 96 144 Users 32 96 144 Partitions 16 16 16 Wireless zones 24 32 32 Key fobs 24 24 24 Memory total of which non volatile 500 250 500 250 999 512 12 9 Comparison between the Hunter Pro...

Page 33: ...any touchtone or cellular phone A remote control call can be initiated by both calling the panel and receiving a call from the panel There are two modes to remote control they are set by the Installe...

Page 34: ...keypad in use is displayed on all the keypads If the panel does not receive any command for a period of 60 seconds it disconnects the call It then remains in standby mode with the above message displa...

Page 35: ...ial 1 59 1 75 2 60 2 76 3 61 3 77 4 62 4 78 5 63 5 79 6 64 6 80 7 65 7 81 8 66 8 82 Send SMS message with the system status to your phones Phone no Dial 1 91 2 92 3 93 4 94 14 2 1 Examples Activate th...

Page 36: ...Expander X Tamper Expander X s box or tamper is open Expander X Fault Expander X is faulty EXP X Voltage Low voltage to the I O 8N zone expander Expander X Mains Expander X has no Mains voltage Expan...

Page 37: ...is faulty IO R X Tamper The I O R relay expander tamper is open IO R X Voltage Low voltage in the I O R relay expander IO R X Mains IO R X has no Mains voltage IO R X Batt IO R X has low battery Wirel...

Page 38: ...Location 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 No Zone Location 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61...

Page 39: ...125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 Installer Details Name ________________________ Phone ____________________________ Cellular ___________________________...

Page 40: ...n and operation instructions and among other things test the Product and the whole system at least once a week For various reasons including but not limited to changes in environment conditions electr...

Reviews: