Technical details
Operating Manual PSEN op4B/1 Series
1003356-EN-02
67
Environmental data
630810
630811
Airgap creepage
Pollution degree
2
2
Protection type
In accordance with the standard
EN 60529
EN 60529
Housing
IP65
IP65
Mechanical data
630810
630811
Connection Type
Receiver
M12, 5-pin male connector; M12,
8-pin male connector
M12, 5-pin male connector; M12,
8-pin male connector
Transmitter
M12, 4-pin male connector; M12,
5-pin male connector
M12, 4-pin male connector; M12,
5-pin male connector
Material
Top
Aluminium
Aluminium
Dimensions
Height
653 mm
953 mm
Width
35 mm
35 mm
Depth
41,2 mm
41,2 mm
Weight
3.710 g
4.410 g
11.1
Safety characteristic data
NOTICE
You must comply with the safety-related characteristic data in order to
achieve the required safety level for your plant/machine.
Operating
mode
EN ISO
13849-1:
2008
PL
EN ISO
13849-1:
2008
Category
EN 62061
SIL CL
EN 62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
13849-1:
2008
T
M
[year]
2-ch. OSSD
PL e
Cat. 4
SIL CL 3
2,62E-09
SIL 3
–
20
All the units used within a safety function must be considered when calculating the safety
characteristic data.
INFORMATION
A safety function's SIL/PL values are
not
identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.