Commissioning
7.1
Setting the functions
7.1.1
Open DIP switch cover
The DIP switches must be operated to set the functions of the safety light grid.
[1]
Fig.: Open DIP switch cover
Legend:
[1]: Groove on the DIP switch cover
Procedure:
1. Insert a thin blade slotted-head screwdriver
into the groove on the cover horizontally
and at a right angle to the safety light grid (see diagram).
2. Gently press the tip of the screwdriver downwards and lever the cover open.
7.1.2
Activate muting
Muting only needs to be activated in the case of L-muting.
Procedure for activating L-muting
1. Switch muting to L-muting on the DIP switch.
Set DIP switches 2 and 6 to OFF.
1
2
3
4
5
6
7
8
ON
Fig.: DIP switches 2 and 6 in OFF position = L-muting activated
To use muting, the following requirements apply:
}
the muting lamp must not be defective,
}
the muting inputs must be wired correctly (see
Connector pin assignment [
42]
),
}
the safety light grid must be in normal operation.