Technical details
Operating Manual PSEN op4B/1 Series
1003356-EN-02
62
11
Technical details
Safety light grid without integrated muting sensors
General
630800
630801
Approvals
CE, TÜV, cULus Listed
CE, TÜV, cULus Listed
Category
Type 4
Type 4
Sensor's mode of operation
optical
optical
Height of detection zone
515 mm
815 mm
Resolution
Protection type
Body
Body
Operating range
0,5 - 50 m
0,5 - 50 m
Resolution of protected field
515 mm
415 mm
Electrical data
630800
630801
Supply voltage
Voltage
24 V
24 V
Kind
DC
DC
Max. overall line capacitance
Clmax
65 nF
65 nF
Optical data
630800
630801
Opening angle
-2,5 - 2,5 deg
-2,5 - 2,5 deg
Used wavelength range
880 nm
880 nm
Semiconductor outputs
630800
630801
OSSD safety outputs
2
2
Switching current per output
500 mA
500 mA
Times
630800
630801
Response time t1
14 ms
14 ms
Environmental data
630800
630801
Ambient temperature
Temperature range
-10 - 55 °C
-10 - 55 °C
Storage temperature
Temperature range
-25 - 70 °C
-25 - 70 °C
Climatic suitability
Humidity
95 % r. h. at 50 °C
95 % r. h. at 50 °C
Condensation during operation
Not permitted
Not permitted
Vibration
In accordance with the standard
EN 60068-2-6
EN 60068-2-6
Frequency
10 - 55 Hz
10 - 55 Hz
Amplitude
0,35 mm
0,35 mm
Shock stress
In accordance with the standard
EN 60068-2-29
EN 60068-2-29
Acceleration
10g
10g
Duration
16 ms
16 ms