Operation
Operating Manual PSEN op4B/1 Series
1003356-EN-02
57
Display
LED Status
Meaning
Action
[1]
[2]
[1]
Lights
green
General transmit-
ter error
Check that the supply
voltage complies with the
information stated in the
Technical
details [
62]
.
Switch the safety light
grid off and then on
again.
If the display is un-
changed, contact Pilz.
[2]
Flashes
yellow
[1]
[2]
[1]
Off
Supply voltage
outside the per-
mitted range (see
Technical
details [
62]
)
[2]
Off
[1]
[2]
[1]
Lights
green
Supply voltage
outside the per-
mitted range (see
Technical
details [
62]
)
[2]
Off
LED indicators in fault condition - Transmitter
8.3.2
Perform reset
Prerequisites
}
Incorrect function of safety light grid
}
There must be nobody within the danger zone
Procedure
Press the TEST/START button for at least 5 seconds and then release it.
}
The OSSDs switch on, the green LED lights and the connected machine starts up.