The distance can be undershot in certain application cases (see diagrams).
250
DEVICE
SAFETY GATE
INPUT
90
DEVICE
SAFETY GATE
INPUT
195
125
DEVICE
SAFETY
GA
T
E
INPUT
}
Make sure that the safety switch and actuator cannot be used as an end stop.
}
Please note the installation measures in accordance with EN ISO 14119 for a safety
switch design 4 and with level of coding High.
}
Please note the permitted bending radii for the cable (see
avoid excessive force on the individual strands.
}
Make sure that the bend protection is not damaged. Such damage can cause the whole
product to fail.
}
For simpler installation, the mounting brackets (see
WARNING!
Loss of safety function due to non-permitted enlargement of the as-
sured release distance when using both switching lobes (aligned at
semicircle marking)
Depending on the application, serious injury or death may result.
– Install a mechanical stop when using the response range at the semi-
circle marking, to avoid unintended switching off at the limit of the re-
sponse range and to prevent the maximum release distance from en-
larging impermissibly by using both switching lobes.