background image

- 12 -

Man

ual de Instr

ucciones original/Istr

uzioni originali/Or

iginele bedr

ijfshandleiding

20 676-04-2010-08 Pr

inted in Ger

man

y

+49 711 3409-444

Asistencia técnica

Supporto tecnico

Technische Support

+49 711 3409-444

+49 711 3409-444

...

Estamos representados en

muchos países por nuestros

socios comerciales.

Obtendrá más información a

través de nuestra Homepage

o entrando en contacto con

nuestra casa matriz.

In veel landen zijn wij

vertegenwoordigd door

handelspartners.

Voor meer informatie kunt

u onze homepage raadplegen

of contact opnemen met

ons hoofdkantoor.

In molti Paesi siamo rappresentati

da partner commerciali.

Per maggiori informazioni potete

contattarci direttamente o tramite

la nostra Homepage.

...

...

www.pilz.com

Pilz GmbH & Co. KG

Felix-Wankel-Straße 2

73760 Ostfildern, Germany

Telephone: +49 711 3409-0

Telefax: +49 711 3409-133

E-Mail: [email protected]

www

10

1

10

100

1000

10000

0.1

DC13: 24 V

AC15: 230 V

AC1: 230 V

DC1: 24 V

Número de ciclos x 10

3

Numero dei cicli di commutazione x 10

3

Aantal schakelingen x 10

3

Corriente nominal de ser

vicio (A)

Corrente di eser

cizio nominale (A)

Nominale bedrijfsstr

oom (A)

Vida útil de los relés de salida/Durata dei relè di uscita/Levensduur van de uitgangsrelais

Corriente térmica convencional de los contactos de seguridad/Corrente termica convenzionale dei contatti
di sicurezza/Conventionele thermische stroom van de veiligheidscontacten (AC1, DC1)

 Número de contactos/Numero dei contatti/Aantal contacten

 I

th

 (A)

8

7

 

6

5

4

3

2

1

5 A

5,4 A

5,8 A

6,4 A

7,1 A

8 A

8 A

8 A

Declaración CE de conformidad:

Estos productos cumplen los requisitos de
la Directiva de Máquinas 2006/42/CE del
Parlamento Europeo y del Consejo.
La declaración CE de conformidad completa
pueden encontrarla en la página web de
Internet www.pilz.com
Apoderado: Norbert Fröhlich,
Pilz GmbH & Co. KG, Felix-Wankel-Str. 2,
73760 Ostfildern, Deutschland

Dichiarazione di conformità CE:

Questo(i) prodotto(i) soddisfa i requisiti della
Direttiva 2006/42/CE del Parlamento e del
Consiglio Europeo sulle macchine.
Il testo integrale della Dichiarazione di
conformità CE è disponibile in Internet
all’indirizzo www.pilz.com
Mandatario: Norbert Fröhlich,
Pilz GmbH & Co. KG, Felix-Wankel-Str. 2,
73760 Ostfildern, Germania

EG-conformiteitsverklaring:

Deze produkten voldoen aan de eisen van
de Europese Machinerichtlijn 2006/42/EG.
De volledige EG-conformiteitsverklaring
vindt u op wwww.pilz.com
Gevolmachtige:  Norbert Fröhlich,
Pilz GmbH & Co. KG, Felix-Wankel-Str. 2,
73760 Ostfildern, Duitsland

Summary of Contents for 773630

Page 1: ...exceeded by the expander module Unit Description The PNOZ po3 1p expander module is fitted in a P 01 housing The base unit provides its power supply via the PNOZpower bus Features Relay outputs 8 saf...

Page 2: ...In other mounting positions the values given in the technical details for the switching capability may not be achieved The PNOZ po3 1p expander module can be installed in any position on the PNOZpowe...

Page 3: ...switched on or off correctly by closing or opening the input circuits on the base unit For safety reasons the unit will not start if any of the following faults is present Contact function faulty FAUL...

Page 4: ...dung Fig 3 ist ein Anschlussbeispiel f r h here Kontaktstr me Application La fig 3 repr sente un exemple de raccorde ment pour les courants de contact de forte intensit 94 3 70 45 1 77 121 4 76 10 1 1...

Page 5: ...e Housing Bo tier Klemmenbereich Terminals Bornes Geh usematerial housing material mat riau du bo tier Geh use Housing Bo tier Front front panel face avant Querschnitt des Au enleiters Schraubklemmen...

Page 6: ...nt thermique conventionnel en cas de charge sur plusieurs contacts AC1 DC1 Anzahl der Kontakte number of contacts nombre des contacts 8 7 6 5 4 3 2 1 Ith A 5 A 5 4 A 5 8 A 6 4 A 7 1 A 8 A 8 A 8 A EG K...

Page 7: ...OZ po3 1p pu essere utilizzato soltanto congiunta mente ad un dispositivo di base o ad un modulo di comando del sistema di sicurezza modulare PNOZpower Il PNOZ po3 1p concepito per essere utilizzato i...

Page 8: ...izione di lavoro I contatti di sicurezza 13 14 83 84 si chiudono I LED CH 1 e CH 2 si accendono Se i circuiti di ingresso si aprono i rel K1 e o K2 si diseccitano I contatti di sicurezza forzati 13 14...

Page 9: ...60 75 C Attenersi assolutamente alle indicazioni riportate nel capitolo Dati tecnici Procedura Il dispositivo attivato quando presente la tensione di alimentazione tramite il bus PNOZpower LED POWER...

Page 10: ...rrientes de contacto Malfunzionamento dei contatti il LED FAULT lampeggia Poich il PNOZ po3 1p viene cablato con un dispositivo base in caso di saldatura dei contatti dopo l apertura del circuito di i...

Page 11: ...adio Inbouwruimte bijv schakelkast Carcasa Alloggiamento Kast Zona de bornes Terminali Aansluitklemmen Material de la carcasa Materiale della custodia ehuizingsmateriaal Carcasa Custodia Behuizing Fre...

Page 12: ...salida Durata dei rel di uscita Levensduur van de uitgangsrelais Corriente t rmica convencional de los contactos de seguridad Corrente termica convenzionale dei contatti di sicurezza Conventionele th...

Reviews: