Regulation valve enables continuous feed speed into cut or arm stabilization in any position by mechanical turning. Examples of feed
speeds are in Chapter 6.6. The optimal value may be easily set by hearing. The saw band movement must be noiseless and without
vibrations. This state may be achieved by reducing or increasing the pressure (arm feed speed). Term for right cutting pressure is the
correct feed speed and optimal band tooth size.
5.9. Regulation valve - saw band feed into cut
SPEED UP
OF ARM FEED
SLOW DOWN
OF ARM FEED
STOP
OF ARM FEED
A
5.10. Cooling equipment
The basis of the cooling equipment is a pump and the coolant tray located in the machine base. The coolant tray can be taken out
separately. The coolant pump conveys the coolant through hoses, valves and guide heads to the band. The coolant quantity is
controlled by these valves. The coolant provides band cooling and lubrication and chip flushing. The pump switches on and off
simultaneously with the band drive start or shutdown.
Hazards due to dangerous matters cannot be excluded while handling coolants. Observe the manufacturer's
and/or your company's instructions and recommendations concerning handling of coolants.
On the coolant tank is overflow hole which secure the proper quantity of coolant fluid. This is to protect the
coolant pump from being overflow and damaged. In case of infusion of bigger volume the coolant fluid may
run under the band saw.
INPUT HOSE
TAPS
SIEVE
COOLANT FLUID TANK
TRASH HOSE
SETTING POT
OVERFLOW HOLE
PUMP
EXTRA COOLANT