Start-up PikoLoad
Guideline Installation PikoLoad
Page 28 / 32
Version 1
4.5.1
LED display (with Company Card)
Figure 27: LED display
The LED’s indicate the following status information (USB interface to the left)
off
off
Ignition off
No power supply -> check the wiring harness
off
red
Ignition on
Initialization and self test is running
red
red
Error, e.g.
•
No card inserted -> check
•
No company card inserted -> check
•
Company card wrong inserted -> check
•
No CAN-Data -> check wiring harness
-> check tachograph whether remote downloadable
•
USB-error -> check USB-stick (Formatting, maybe the USB-stick is
full)
•
internal error-> replace the unit
off
green
Authentication running or is checked (ca. 2 minutes duration)
green
green
Authenticated, data are downloading
orange
green
USB Stick is in writing mode, download is still running
Do not unplug the USB-Stick, you might loose data
green
red
Tacho is not locked to the company card or locked to a different company
card
Note:
If not locked, all unlocked data are downloaded
Driver cards are downloaded independent from the lock
orange
red
Company card expired (5 years validity check)
Company card damaged -> please check and replace
Tacho is longer than 15 minutes in „pending mode“
Company card, control card or workshop card is inserted in the tachograph
Tacho is waiting on input
Internal Tacho error -> check in workshop
orange
orange
„Service Mode“