28
TECHNICAL MANUAL MT103
Pilot 204/A, 204/A/1
Code
Colour
De Lo
d
i
it
Setting range in bar
2701260
WHITE
3.5
7.5
7.5
0.3 ÷
1.2
2701530
YELLOW
4
7
7
0.7
÷
2.8
2702070
ORANGE
5
7
7
1.5
÷
7
2702450
RED
35
60
6
7
7
4
÷
14
2702815
GREEN
7
7
7
8
÷
20
2703220
BLACK
8
6
6
15
÷
33
2703420
BLUE
8.5
6
6
22
÷
43
4.4.3 Tab. 7 SETTING SPRINGS
Pilot 205/A
Code
Colour
De Lo
d
i
it
Setting range in bar
2702820
BLUE
7
7
9
20 ÷
35
2703045
BROWN
35
100
7.5
7.5
9.5
30
÷
43
2703224
GREY
8
7.5
9.5
40
÷
60
Pilot 207/A
Code
Colour
De Lo
d
i
it
Setting range in bar
2703224
GREY
35
100
8
7.5
9.5
41
÷
74
The REFLUX 819 regulator and the monitor PM/819 uses the 204/A, 205/A and 207/A pilots. The regulation range
of the different pilots is given in the tables below.
De =
Ø external diameter
d =
Ø wire diameter
i =
active coils
Lo =
Lenght
it =
total coils
| [email protected] | Phone: 877.566.3837 | Fax: 925.407.2903