24
Commands for the
Commands for the
Commands for the
Commands for the LDP
LDP
LDP
LDP----QCW
QCW
QCW
QCW
The following table contains a command reference for the LDP-QCW.
Command
Command
Command
Command
Pa
Pa
Pa
Parameter
rameter
rameter
rameter
Description
Description
Description
Description
ghwver
-
returns the hardware version number
gswver
-
returns the software version number
gserial
-
returns the serial number
gname
-
returns the device name
ps
-
prints out all settings
loaddef
-
load default values
savedef
-
save all settings as default values
enautodef
-
enables the automatic loading of default settings on power on
disautodef
-
disables the automatic loading of default settings on power on
gerrtxt
-
returns the error register in text-form
gerr
-
returns the error register as a 32bin number
glstat
-
returns the laser status register
slstat
32bit number
sets the laser status register to the given value.
gtrgmode
-
returns the actual trigger mode. See below for more information.
strgmode
mode
sets the trigger mode to the given value. See below for more
information. The return value is the new mode.
gtrgcount
-
returns “0” if counting is disabled or “1” if enabled.
strgcount
0 or 1
enabled (1) or disables (0) the counting mode
gtrgedge
-
returns “0” for negative edge or “1” for positive edge
strgedge
0 or 1
sets the trigger edge for external trigger.“0” = negative, “1” =
positive
lon
-
enabled the output (needed after any change in trigger modes)
loff
-
disables the output
curint
-
switches to internal current set point
curext
-
switches to external current set point
gmode
-
returns the current regulator mode.
Mode 0: manual
Mode 1: semi-automatic
See chapter “current regulator” for more information
smode
0 … 2
sets the current regulator mode to the given value.
Mode 0: manual
Mode 1: semi-automatic
See chapter “current regulator” for more information