20
Defaults
def. pwron
def. pwron
def. pwron
def. pwron
If enabled the LDP-QCW loads default values every time it is powered on. These values are CRC
checked at power-up. If this check fails the values are not loaded and an error message is displayed.
Save defaul
Save defaul
Save defaul
Save defaults
ts
ts
ts
When the Jogdail is turned or the ENTER key is pressed all current values are saved.
Load defaults
Load defaults
Load defaults
Load defaults
When the Jogdail is turned or the ENTER key is pressed all current values are overwritten by the saved
ones. If the output was enabled at this time it becomes disabled.
Regler
IIII----Delay
Delay
Delay
Delay
This value represents the switching-point of the integral part of the current regulator. It is defined in
percent of the setpoint current. See chapter current regulator for more information.
IIII
This value defines the strength of the integral part of the current regulator. The value ranges from 0
to 4095.
FFwd
FFwd
FFwd
FFwd
This value represents the feed forward voltage of the current regulator. See chapter current regulator
for more information.
Voltage
Voltage
Voltage
Voltage
This value represents the precharge voltage of the current regulator. See chapter current regulator for
more information.
Regler2
P
PP
P
This value defines the strength of the proportional part of the current regulator. The value ranges
from 0 to 4095.