10 Technical Data
N-422 Linear Drive
MP116E
Version: 1.1.1
33
Degree of protection
according to IEC 60529
IP30
10.2
Drive Performance
Velocity and dynamic force
The following graph can be used to estimate the dynamic force (push/pull force, force in N) of
the N-422 at different velocities.
N-422.50
Figure 9: Velocity vs. dynamic force (push/pull force) of the N-422
10.3
Lifetime
The N-422 can achieve a lifetime of 2000 m under optimum operating conditions and with full
use of the travel range. Optimum operating conditions of the N-422:
Duty cycle: Maximum 50 %
Running time: Maximum 10 seconds
Ambient temperature: Room temperature
Air pressure: Normal pressure
Proper installation of the N-422 (p. 13)