10 Technical Data
32
Version: 1.1.1
MP116E
N-422 Linear Drive
N-422.50
Unit
Toleranc
e
Cable length
1.5
m
±10 mm
Recommended
controller/driver
E-870
Dimensions
19 × 13 × 16 (base body) plus
rod / coupling element
mm
10.1.2
Maximum Ratings
N-422 linear drives are designed for the following operating data:
Device
Maximum
Operating Voltage
Maximum Operating
Frequency
Maximum Power
Consumption
N-422
48 V
pp
23 kHz
15 W
10.1.3
Ambient Conditions and Classifications
Pay attention to the following ambient conditions and classifications for the N-422:
Area of application
For indoor use only
Maximum altitude
2000 m
Air pressure
1100 hPa to 0.1 hPa
(corresponds to roughly 825 Torr to 0.075
Torr)
Relative humidity
Highest relative humidity 80% for
temperatures up to 31°C
Decreasing linearly to 50% relative humidity
at 40°C
Operating temperature
0 °C to 50 °C
Storage temperature
-20°C to 75°C
Transport temperature
-20°C to 75°C
Overvoltage category
II
Protection class
I
Degree of pollution
1