Manual MSD2
+
MA 2126
–A005 EN
34
9 Putting into Service
Please follow the described order when you put into service the MSD2
+
:
1. Connect the MSD2
+
acc. to protective measure in chap. 5.
2. All connectors and screw terminals must only be connected or removed when the
module is disconnected from the mains.
3. If you have the MSD2
+
option ServiceBus ("SB") in front of you, continue with step 8.
4.
MSD2
+
option rotary switch mode („KS“):
The table in chap. 8.5 and
Fehler!
Verweisquelle konnte nicht gefunden werden.
is available for setting the rotary
switches.
5. Set the I
Run
rotary switch to the required run current. The phase current should not
exceed the maximum permissible current of the motor.
6. The stop current is set at the I
Stop
rotary switch. As a rule, the following setting is
recommended: Stop current = 50 % of the run current.
7.
Set the desired step resolution and preferred direction of rotation at the „Step“ rotary
switch. Continue with step 10.
8.
MSD2
+
option ServiceBus mode („SB“):
Download drivers and software from the
Phytron website (
https://www.phytron.eu/support/downloads/software-download/
9. Install the communication software ServiceBus-Comm
TM
and start the program after
successful installation.
10. Connect the input signals to the control pulses and direction inputs.
11. Check that the mains voltage corresponds to the specifications on the type plate of the
MSD2
+
before the power stage is switched on.
12. Connect the supply voltage to the 3-pole Phoenix connector
„Mains“ (see chap.
Fehler!
Verweisquelle konnte nicht gefunden werden.
).
13. Switch on the mains voltage.
14. Start up.
WARNING
– Risk of damage due to incorrect motor current setting.
The motor gets too hot!
- Deactivate the Boost function if it is aktivated continuously.
- Adjust the motor current setting to the motor type (see motor
’s data).
DANGER - Danger of electric arcing!
During electrical installation the cable, connector or similar may be energised.
- Always switch off the supply voltage before connecting or disconnecting any
wires or connectors at the power stage. Do not unplug the connector while
powered