Manual DIOM01
MA 1271-A003 EN
12
4.4 Functional Description
Digital inputs and outputs:
•
8 digital inputs 24 V
DC
•
8 digital outputs 24 – 30 V
DC
, at 1 A max., 2 A max. per module. Up to 4 A per
module is possible with a direct power supply.
•
Internal 24 V
DC
power supplies to the inputs and outputs when centrally delivered
from the supply modules POWM01 or POWM02.
•
External 24 – 30 V
DC
power supply of the inputs and outputs when delivered directly
to the DIOM01/DIOM0a. Condition: external power supply = internal power
1 V.
Counting function:
•
The DIOM01/DIOM0a can also be used as a 1-fold counter module.
•
The counting function is at input 1.