background image

phytron

 

 

 
10/2015 

 

Manual MA 1271-A003 EN 

 

 
 
 
 
 
 
 
 
 
 
 
 

phy

MOTION

TM

 

Digital I/O Module 

DIOM01.1 / DIOM0a.1 

 

Firmware Version: 

V1.0.0 (Loader) V1.0.0 (Loader)

 

V1.0.0 (System) V1.0.0 (System)

 

 
 
 

 

 

 

 

 

 

 

 

TRANSLATION OF THE ORIGINAL GERMAN MANUAL 

Summary of Contents for DIOM01.1

Page 1: ...phytron 10 2015 Manual MA 1271 A003 EN phyMOTIONTM Digital I O Module DIOM01 1 DIOM0a 1 Firmware Version V1 0 0 Loader V1 0 0 Loader V1 0 0 System V1 0 0 System TRANSLATION OF THE ORIGINAL GERMAN MANUAL ...

Page 2: ...de phyMOTION are the descriptions of the features and specifications for the phyMOTIONTM stepper motor controller Every possible care has been taken to ensure the accuracy of this technical manual All information contained in this manual is correct to the best of our knowledge and belief but cannot be guaranteed Furthermore we reserve the right to make improvements and enhancements to the manual a...

Page 3: ...k Indicates a high risk of serious injury or death from electric shock WARNING Serious injury possible Indicates a possible risk of serious injury or death WARNING Serious injury from electric shock Indicates a possible risk of serious injury or death from electric shock CAUTION Possible injury Indicates a possible risk of personal injury i CAUTION Possible damage Indicates a possible risk of dama...

Page 4: ...sign installation and operation of systems may only be performed by qualified and trained personnel These persons should be able to recognize and handle risks emerging from electrical mechanical or electronic system parts The qualified personnel must know the content of this manual and be able to understand all documents belonging to the product Safety instructions are to be provided The trained p...

Page 5: ...e risk of dangerous voltages may be on the device Touching these components carrying high voltages can cause serious injury or death from electric shock Always observe the safety concept SELV PELV to ensure safe isolation and separation of low voltage supplies from the mains WARNING Serious injury from electric shock During electrical installation cables connectors etc can be live Before starting ...

Page 6: ...n 12 5 Installation 13 5 1 Mechanical Installation of the DIOM01 DIOM0a Modules 13 5 2 Electrical Installation 15 5 2 1 Connectors Overview 15 5 2 2 Pin Assignment 16 5 2 3 Input Wiring 17 5 2 4 Output Wiring 17 6 Commissioning 18 6 1 Diagnostics by the LEDs 19 6 2 Parameterising of the Modules 20 7 Service 21 8 Warranty Disclaimer and registered trademarks 22 8 1 Disclaimer 22 8 2 Warranty 22 8 3...

Page 7: ...a Front view of the panel Digital inputs and outputs 8 digital inputs 24 VDC 8 digital outputs 24 30 VDC at 1 A max 2 A max per module Up to 4 A per module is possible with a direct power supply Internal 24 VDC power supplies to the inputs and outputs when centrally delivered from the supply modules POWM01 or POWM02 External 24 30 VDC power supply of the inputs and outputs when delivered directly ...

Page 8: ...Manual DIOM01 MA 1271 A003 EN 8 4 Technical Data 4 1 Declaration of Conformity ...

Page 9: ...003 EN 4 2 Mechanical Data Dimension 100 x 100 mm without front panel Weight 56 g without and 79 g with front panel Mounting Plug in module into the modular stepper motor controller phyMOTIONTM Mounting position Vertical ...

Page 10: ...it is supplied directly to the DIOM01 DIOM0a module Each output is designed for a maximum of 1 A Power consumption 75 mA for the internal 5 VDC Power consumption of the I Os 5 mA for 24 VDC Cable length digital inputs 30 m if longer 100 m max use shielded cable and contact shield close to the controller Status LEDs See chapter 6 1 Interfaces 8 digital outputs O1 to O8 Output level 24 VDC for inter...

Page 11: ...l and 2A max at the central supply via the delivering modules POWM01 or POWM02 30 VDC external and 4 A max when delivered directly to the DIOM01 DIOM0a module The external power supply must always be higher than the internal power supply Rear bus connection Proprietary phytron bus Communication and Programming Programming Via phytron s programming environment phyLOGICTM ToolBox Communication Maste...

Page 12: ...ct power supply Internal 24 VDC power supplies to the inputs and outputs when centrally delivered from the supply modules POWM01 or POWM02 External 24 30 VDC power supply of the inputs and outputs when delivered directly to the DIOM01 DIOM0a Condition external power supply internal power supply 1 V Counting function The DIOM01 DIOM0a can also be used as a 1 fold counter module The counting functio...

Page 13: ...sion module or after repair or service unpack the module in ESD protected area only CAUTION Possible damage by ESD The modules of the phyMOTIONTM consist of sensitive electronic components that can be destroyed by electrostatic discharge voltages Always store and transport single modules in ESD protective packaging Always handle the components in compliance with the ESD protection measures No liab...

Page 14: ...tes after power off to allow the capacitors to discharge and ensure that there are no residual charges on cables connectors and boards Make sure not to leave free slots in between modules so the module addressing sequence can work correctly Push the module card carefully into the guide rail until the rear contacts the housing s frame of the phyMOTIONTM In the last few millimetres the module s plug...

Page 15: ... If all the connections are made the last step is to plug in the power supply to the mains 5 2 1 Connectors Overview Connector Number of pins Connector on the module Phoenix Mating connector Phoenix Mating connector ID number I Os 2x8 MCDN1 5 8 G1 3 5P26 FMC1 5 8 ST 3 5 10005881 Power supply 2x2 MCDN1 5 2 G1 3 5P26 FMC1 5 2 ST 3 5 10007077 The mating connector is included in delivery of the module...

Page 16: ...Manual DIOM01 MA 1271 A003 EN 16 5 2 2 Pin Assignment Here is the pin assignment of the DIOM01 DIOM0a Fig 2 Pin assignment For wiring please use the above defined mating connectors ...

Page 17: ...reshold DIOM01 2 4 V DIOM0a 11 V Fig 3 Input wiring 5 2 4 Output Wiring Fig 4 Output wiring i CAUTION Possible damage Damage of the module because of incorrect connection Do not swap the 8 pin connector for the 8 inputs with the 8 pin connector for the outputs ...

Page 18: ... a supporting manual phyLOGICTM ToolBox Communication Software for the phyMOTIONTM Stepper Motor Controller For programming the sequential program please read Further manual Detailed information on this subject is in a supporting manual phyLOGICTM Command Reference for the phyMOTIONTM Controller i CAUTION Possible damage Some modules are set to a default value on delivery So e g the motor current ...

Page 19: ...e by colours and blinking Fig 5 Status LEDs Status LEDs I O LEDs top left top right off No power supply connected I Os not active green Isolated supply ok OK Output O1 to O8 active red Flashing slowly 2 Hz module is not addressed Flashing fast 5 Hz error Input I1 to I8 active orange Input and output I1 O1 to I8 O8 active ...

Page 20: ...Manual DIOM01 MA 1271 A003 EN 20 6 2 Parameterising of the Modules No parameterisation for the DIOM01 DIOM0a module is necessary ...

Page 21: ...moval of a module Switch off the phyMOTION s supply voltage Disconnect the supply voltage Loosen the screw on top and the screw on the bottom of the module s front plate Pull the card carefully by the handle If you want to use the phyMOTION after removing a module the gap has to be sealed with a blanking plate before power supply is reconnected and switched on To send a module to phytron use ESD p...

Page 22: ... failure due to defects in material or caused by the production process This warranty does not include damage caused by the customer for example not intended use unauthorized modifications incorrect handling or wiring 8 3 Registered trademarks In this manual several trademarks are used which are no longer explicitly marked as trademarks within the text The lack of these signs may not be used to dr...

Page 23: ...8 13 Current consumption 11 I Input wiring 18 Installation 14 16 Intended use 5 L LED 20 M Mating connector 16 MCM01 7 14 O Output wiring 18 P Pin assignment 17 Power consumption 11 Power supply 11 Progamming environment 12 Programming 19 S Safety instructions 5 Service 22 Short circuit 11 Supply module 7 13 W Warranty 23 ...