phyCORE-TriCore Development Board
3.
The CAN transceiver populating the phyCORE-TC1130 or
phyCORE-TC1796 is disabled; CAN signals generated by the
CAN transceiver (U3) on the Development Board extend to
connector P2A
with galvanic separation.
This configuration
requires connection of an external CAN supply voltage of
7 to 13 V. The external power supply must be
only
connected to
either P2A
or
P2B.
Jumper Setting
Description
JP25
1 + 3
2 + 4
Pin 7 of DB-9 plug P2A connected with CAN-H0 from
CAN transceiver U5 on the Development Board
JP24
1 + 3
2 + 4
Pin 2 of DB-9 plug P2A connected with CAN-L0 from
CAN transceiver U5 on the Development Board
JP14
1 + 2
Supply voltage for CAN transceiver and opto-coupler
on the Development Board derived from external source
(CAN bus) via on-board voltage regulator
JP19
open
CAN transceiver and opto-coupler on the Development
Board disconnected from local GND potential
Table 7:
Jumper Configuration for CAN Plug P2A Using the CAN
Transceiver on the Development Board with Galvanic Separation
Pin 9:
VCAN+
Pin 3:
VCAN-
Pin 7:
CAN-H0 (galvanically separated)
Pin 2:
CAN-L0 (galvanically separated)
Pin 6:
VCAN-
Figure 12: Pin Assignment of the DB-9 Plug P2A (CAN Transceiver on
Development Board with Galvanic Separation)
18
©
PHYTEC Meßtechnik GmbH 2009 L-730e_0
1
2
3
4
7
6
5
8
9