MV-D752-28 User’s Manual
REV: 1.0
Page 18/61
5.5
Overview of the trigger modes
The following overview summarizes the functions of the various trigger modes.
RE_xxxx: Rising Edge of signal
FE_xxxx: Falling Edge of signal
Polarity
TRIGGER START
EXPOSURE START
EXPOSURE STOP
EXSYNC Mode internal exposure time via Register
- 1
FE_EXSYNC
FE_EXSYNC
EXPOSURE_END
+1 RE_EXSYNC RE_EXSYNC EXPOSURE_END
EXSYNC – EXPOSURE Start/Stop Trigger for exposure time
- 1
FE_EXSYNC
FE_EXSYNC
FE_EXPOSURE
+1 RE_EXSYNC RE_EXSYNC RE_EXPOSURE
EXSYNC-EXPOSURE
- 1
FE_EXSYNC
FE_EXSYNC RE_EXSYNC
+1 RE_EXSYNC RE_EXSYNC FE_EXSYNC