7 Software
If LUT values should be retained in the camera after disconnecting the power,
then they must be saved with
UserSetSave
7.5.2
Full ROI LUT
This section describe the settings for one LUT that is applied to the full ROI.
1.
Set
LUT_EnRegionLUT
(in category
RegionLUT
) to False. This is required to use the full ROI LUT.
2.
Set
LUTEnable
(in category
LUTControl
) to False. This is not mandatory but recommended.
3.
Select LUT 0 by setting
LUTSelector
(in category
LUTControl
) to 0.
4.
Set LUT content as described in Section 7.5.4.
5.
Turn on LUT by setting
LUTEnable
to True.
7.5.3
Region LUT
The Region LUT feature is described in Section 5.8.4. Procedure to set the Region LUT:
1.
Set
LUT_EnRegionLUT
(in category
RegionLUT
) to False. This is not mandatory but
recommended.
2.
Set
LUTEnable
(in category
LUTControl
) to False. This is not mandatory but recommended.
3.
Select LUT 0 by setting
LUTSelector
(in category
LUTControl
) to 0.
4.
Set properties LUT_X, LUT_W, LUT_Y and LUT_H (all in category
RegionLUT
) to desired
value.
5.
Set LUT content as described in Section 7.5.4.
6.
If two Region LUT are required, then select LUT 1 by setting
LUTSelector
(in category
LUTControl
) to 1 and repeat steps 4 and 5.
7.
Turn on LUT by setting
LUTEnable
to True.
8.
Turn on Region LUT by setting
LUT_EnRegionLUT
(in category
RegionLUT
) to False.
7.5.4
User defined LUT settings
This section describes how to set user defined LUT values. It is assumed that the LUT was
selected as described in Section 7.5.2 or Section 7.5.3.
For every LUT value the following steps must be done:
1.
Set
LUTIndex
(in category
LUTControl
) to desired value. The
LUTIndex
corresponds to the
grey value of the 12 bit input signal of the LUT.
2.
Set
LUTValue
(in category
LUTControl
) to desired value. The
LUTValue
corresponds to the
grey value of the 8 bit output signal of the LUT.
The
LUTIndex
is auto incremented internally after setting a
LUTValue
. If consec-
utive
LUTIndex
are written, then it is required to set
LUTIndex
only for the first
value. For the next values it is sufficient to set only the
LUTValue
.
98
Summary of Contents for DR1-D3360-192-G2-8
Page 1: ...MAN071 03 2015 V1 0 Photonfocus MV1 D3360 G2 Camera Series CMOS camera with GigE interface...
Page 10: ...3 How to get started GigE G2 Figure 3 3 PFInstaller components choice 10...
Page 22: ...4 Product Speci cation Figure 4 1 Photonfocus D3360 GigE camera series with C mount lens 22...
Page 76: ...5 Functionality 76...
Page 92: ...6 Hardware Interface 92...
Page 112: ...9 Warranty 112...
Page 114: ...10 References 114...
Page 119: ...C Document Revision History Revision Date Changes 1 0 March 2016 First version 119...