Name
Direction
Description
A0 (Line0)
Power connector -> PLC
ISO_IN0 input signal
A1(Line1)
Power connector -> PLC
ISO_IN1 input signal
A2 (Line2)
Power connector -> PLC
ISO_INC0 input signal
A3 (Line3)
Power connector -> PLC
ISO_INC1 input signal
A4
camera head -> PLC
FVAL (Frame Valid) signal
A5
camera head -> PLC
LVAL (Line Valid) signal
A6
camera head -> PLC
DVAL (Data Valid) signal
A7
camera head -> PLC
Reserved (CL_SPARE)
Q0
PLC ->
not connected
Q1
PLC -> power connector
ISO_OUT1 output signal (signal is inverted)
Q2
PLC ->
not connected
Q3
PLC ->
not connected
Q4
PLC -> camera head
PLC_Q4 camera trigger
Q5
PLC -> camera head
PLC_Q5 (only available on cameras with Counter
Reset External feature)
Q6
PLC -> camera head
Incremental encoder A signal (only available on
cameras with AB Trigger feature)
Q7
PLC -> camera head
Incremental encoder B signal (only available on
cameras with AB Trigger feature)
Table 6.2: Connections to/from PLC
6.6 PLC connections
91
Summary of Contents for DR1-D3360-192-G2-8
Page 1: ...MAN071 03 2015 V1 0 Photonfocus MV1 D3360 G2 Camera Series CMOS camera with GigE interface...
Page 10: ...3 How to get started GigE G2 Figure 3 3 PFInstaller components choice 10...
Page 22: ...4 Product Speci cation Figure 4 1 Photonfocus D3360 GigE camera series with C mount lens 22...
Page 76: ...5 Functionality 76...
Page 92: ...6 Hardware Interface 92...
Page 112: ...9 Warranty 112...
Page 114: ...10 References 114...
Page 119: ...C Document Revision History Revision Date Changes 1 0 March 2016 First version 119...