Trigger timing values
Table 5.8 and Table 5.9 show the values of the trigger timing parameters.
D-160
D-160
Timing Parameter
Minimum
Maximum
t
d
−
iso
−
input
45 ns
60 ns
t
jitter
0
25 ns
t
trigger
−
delay
0
0.42 s
t
burst
−
trigger
−
delay
0
0.42 s
t
burst
−
period
−
time
depends on camera settings
0.42 s
t
trigger
−
offset
(non burst mode)
100 ns
duration of 1 row
t
trigger
−
offset
(burst mode)
125 ns
125 ns
t
exposure
15
µ
s
1)
/ 28
µ
s
0.42 s
t
strobe
−
delay
0
0.42 s
t
strobe
−
offset
(non burst mode)
100 ns
100 ns
t
strobe
−
offset
(burst mode)
125 ns
125 ns
t
strobe
−
duration
200 ns
0.42 s
t
d
−
iso
−
output
45 ns
60 ns
t
trigger
−
pulsewidth
200 ns
n/a
Number of bursts n
1
30000
Table 5.8: Summary of timing parameters relevant in the external trigger mode using the D-160 cameras
(Footnotes:
1)
2 MPix cameras)
.
5.2 Trigger and Strobe
43
Summary of Contents for D-2048 CameraLink Series
Page 1: ...User Manual Photonfocus D L 2048 CameraLink Series CMOS Area Scan Camera MAN054 11 2013 V1 3...
Page 2: ......
Page 4: ...2...
Page 8: ...CONTENTS 6...
Page 16: ...3 How to get started CameraLink Figure 3 4 PFRemote start window 14...
Page 92: ...8 Graphical User Interface GUI 90...
Page 94: ...9 Mechanical Considerations 92...
Page 96: ...10 Warranty 94...
Page 98: ...11 References 96...
Page 102: ...A Pinouts 100...
Page 108: ...B Camera Revisions 106...