5.2 Troubleshooting

No dehumidification, neither hour meter display nor 

compressor run and POWER button does not turn ON.

1.   Unit unplugged or no power to outlet
2.   Defective control board
3.   Loose connection in internal wiring

No dehumidification, neither hour meter display nor 

compressor run with POWER button ON.

1.   Defective control board
2.   Loose connection in internal wiring

Some dehumidification, air mover runs continuously but 

compressor only runs sporadically.

1.   Unit is in defrost cycle, DEFROST light on
2.   Defrost thermistor defective or loose
3.   Loose connection in compressor circuit
4.   Defective compressor overload
5.   Defective compressor
6.   Defective relay
7.   Upper housing is not sealed to lower housing

No dehumidification, air mover runs but compressor does 

not.

1.   Bad connection in compressor circuit
2.   Safety float switch closed, check pump reservoir
3.   Defective compressor capacitor
4.   Defective compressor overload
5.   Defective compressor
6.   Defective control board

Figure 5: Refrigeration system

Air mover does not run. Compressor runs briefly but cycles 

on and off.

1.   Loose connection in blower circuit
2.   Obstruction prevents impeller rotation
3.   Defective air mover

Unit removes some water but not as much as expected.

1.   Air temperature and/or humidity have dropped
2.   Humidity meter and/or thermometer used are out of 

calibration

3.   Unit has entered defrost cycle
4.   Air filter dirty
5.   Defective defrost thermistor
6.   Low refrigerant charge
7.   Air leak such as loose cover
8.   Defective compressor
9.   Restrictive exhaust or inlet ducting

Unit runs but does not pump water.

1.   Hose kinked or plugged
2.   Pump motor defective
3.   Pump check valve plugged
4.   Bad connection in pump circuit
5.   Hose disconnected internally
6.   Defective control board (pump phase)

Unit pumps water automatically but not when PURGE button 

is pushed.

1.   Bad connection in PURGE button circuit
2.   Defective control board

Evaporator coil frosted continuously, low dehumidifying 

capacity.

1.   Defrost thermistor loose or defective
2.   Low refrigerant charge
3.   Dirty air filter or restricted air flow
4.   Upper housing is not sealed to lower housing

Compressor runs with POWER button OFF.

1.   Defective relay
2.   Defective control board
3.   Upper housing not sealed to tower

Summary of Contents for R175

Page 1: ...idifiers of equal size Energy Efficiency Removes 92 pints at AHAM while drawing only 6 3 amps Patented Bypass Technology 230 CFM More processed air speeds drying and provides superior static pressure for ducting More Grain Depression Drier from an LGR gets your jobs drier quicker Focused Airflow Patent focused outlet directs air downward across the wet surface Multiple Ducting Options 12 intake 10...

Page 2: ...ar 100 of Parts and Labor 2nd 5th year 100 of Parts of sealed refrigeration system Size 33 high x 20 wide x 20 deep Weight 105 lbs Patent 7 246 503 7 281 389 7 540 166 3 Operation Place dehumidifier inside structure place condensate hose into a drain or a very large container and turn on To decrease drying times make sure all windows and doors are closed to the outside and seal off the wet area fr...

Page 3: ...reases the evaporator temperature will rise and the thermistor will end the defrost cycle at the temperature set point 3 6 POWER Button Press the POWER button to turn the dehumidifier on or off When starting the dehumidifier the display will show the accumulated hours Press the POWER button again to turn the dehumidifier off The display will also power off 3 7 PURGE Button During normal operation ...

Page 4: ... drain 2 Plug in the unit but do not turn it on 3 Remove the air filter Slowly pour a pint of the chemical through the top so that it drains into the heat exchanger 4 Use PURGE button to remove chemicals in reservoir Run PURGE until hose runs dry 5 Walk out hose to drain completely 6 Replace air filter 5 Service WARNING Servicing the Phoenix R175 with its high pressure refrigerant system and high ...

Page 5: ...gure 5 Refrigeration system Air mover does not run Compressor runs briefly but cycles on and off 1 Loose connection in blower circuit 2 Obstruction prevents impeller rotation 3 Defective air mover Unit removes some water but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle 4 Air f...

Page 6: ...ma Stor LLC at 1 800 533 7533 5 3 Air Mover The motorized impeller has a PSC motor and internal thermal overload protection If defective the complete assembly must be replaced 1 Unplug power cord 2 Remove the four screws attaching the bottom plate to the lower housing 3 Disconnect the impeller leads 4 Remove the four screws holding the impeller to the bottom plate 5 Reassemble the new impeller usi...

Page 7: ...U 14 RED 13 COMPRESSOR BLOWER MOTOR LEVEL SWITCH CONTROL BOARD THERMISTOR CONDENSATE PUMP WHT 10 GRN BLK WHT 2 YEL 9 YEL 8 RUN CAPACITOR RUN CAPACITOR BLK 3 YEL 7 E1 E3 E2 E5 E4 BLK 5 BRN 6 BLK 12 BLU 18 BLK 4 WHT S R C 4026354 C Figure 9 Wiring diagram 7 Wiring Diagram ...

Page 8: ...33 long 1 4024916 12 Coupling Body 1 4 Tube 1 4026306 13 Coupling Insert 1 4 Tube 1 4026986 14 Cord 1 4032297 15 Control Board 1 4026763 16 Capacitor Compressor 45 μF 1 4033032 05 17 Capacitor Impeller 7 5 μF 1 4033031 04 18 Thermistor 1 4031279 Items listed are not shown Description Qty Part No Compressor 1 4029168 Evaporator Coil 1 4028234 Condenser Coil 1 4028235 Accumulator 1 4028297 Condensat...

Page 9: ...The end user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix R175 Dehumidifier part is repaired...

Reviews: