FRONT SIDE OF THE AMPLIFIER
11.
“Copyright 2015, Phoenix Professional Audio GmbH, www.phoenix-pa.com“
Phoenix logo is registered at the German Patent- and Trademark Office (TM)
All brands are property of their respective owners.
10. RECORD OUTPUT
Unbalanced connected (0 dB), is used to connect recording devices. The signal which is available for recording, is the signal sum
of the microphone- and sound carrier inputs before the sound- (EQ)- and MASTER volume control.
11. MASTER SECTION
With this control the master volume can be adjusted, raised or driven. Please consider the digital volume control in DSP audio
(limiter) in the system display (sett
ings VOL for PRESETS 1 and 2
).
12. CONTROL LED`s, PROT and PWR OPERATION DISPLAY
When the PROTECT control indication lights up without input signal, possibly there are system oscillations or other interferen-
ces. Disconnect the load and reduce the amplification to zero. When the LED continues to light, possibly the amplifier has to be
maintained.
13. MAINS ON-/OFF SWITCH WITH OPERATION DISPLAY
After activation of this switch the device is ready for use. Operating voltage 230 VAC/50-60 Hz.
14. 2-BAND EQ
Separate LF- and HF control of the individual microphone- or LINE inputs and MASTER SECTION. At the rear side please select
the DIP switches between MIC.- and LINE sensitivity.
15. PRESET 1 and PRESET 2 switch with LED indication
Manual shift of the presets 1 and 2, if a manual shift of the PRESETS shall be carried out, the current condition is indicated by the
control LED PRESET 1 or PRESET 2 or the
„CLEAR TEXT“
PRESET name on the display.
16. DISPLAY
Multifunctional display with menu navigation and indication for all guided settings in the system by the SETTING/ENTER button