© Copyright 2018, Phoenix Professional Audio GmbH, www.phoenix-pa.com
Phoenix logo is registered with the DE Patent and Trademark Office (TM)
All trademarks are the property of their respective owners
Instruction manual
- 11 -
ILA-1000
™
Please lead parallel lines close together.
A significantly better result (constant field strength) than with single loops is achieved by laying LOOP SEGMENT
loops. The individual segments must be the same size, the distances should be between 2 meters and 5 meters.
Application examples: rows of seats in the theater, church, schools, etc.
IMPORTANT:
Disadvantage of a LOOP SEGMENT loop without phase shifter:
Wherever two loop lines run parallel, the field strength is equal to „0“! The area of the „0“ field strength can be
between a few centimeters to one meter.
IMPORTANT:
Rooms and areas where an induction loop has been installed should be marked accordingly.
CONSTRUCTION SIMPLE LOOP SYSTEM „Single Array System“