Phoenix Mecano Komponenten AG
17
7
Life phases
7.1
Electric cylinder scope of delivery
The electric cylinder is delivered as an individual component. The controls and manual switches and / or accessories are not included in
scope of delivery.
7.2
Transport and storage
The product is to be checked by suitable personnel for visible and functional damage. Damage caused by transport and storage must be
reported to the responsible person and Phoenix Mecano Komponenten AG immediately.
Commissioning damaged electric cylinders is forbidden.
The ambient conditions for the storage of the electric cylinder are prescribed as follows:
•
air must not contain oils
•
contact with solvent-based paints must be avoided
•
lowest / highest ambient temperature:
–40 °C to +85 °C
•
air pressure: from 700 to 1060 hPa
Divergent ambient factors must be approved by Phoenix Mecano Komponenten AG.
7.3
Important information on installation and commissioning
It is essential that you note and follow the following instructions. Otherwise persons can be injured or the
electric cylinder and/or other components damaged.
•
It is essential to implement an emergency stop onsite, which could interrupt reliably the operating voltage in the event of a failure
or malfunction of the incomplete machine!
•
No additional holes may be made in the electric cylinder.
•
After setting up and commissioning, it is essential that the plug of the power supply is freely accessible.
•
The electric cylinder must not be moved to "Stop". Risk of mechanical damage.
•
The electric cylinder may not be opened.
•
The user must ensure that there is no danger when the power supply is active.
•
Pinch and shear points must be avoided in the design of the applications with this electric cylinder. These must be secured and
marked correspondingly.
•
Automatic start-up of the electric cylinder caused by a defect is to be stopped immediately by disconnecting the power supply
(see Emergency stop).
•
If the supply line is damaged, the electric cylinder must be taken out of operation immediately.
•
The pushrod with suspension must be secured against twisting. Non-observance leads to the adjustment of the stroke end
position.
•
The electric cylinder has not been designed for continuous operation. The number of starts per hour determined for your appli-
cation may not be exceeded.