26
8 Connection plans
8.1 Connection type AP.4.017 712
(Supply voltage polarity; 1x Power cable)
Green-Yellow
(GNYE)
Power cable
(sketch)
Brown
(BN)
Blue
(BU)
Power cable
Input / Output
Description
Green-Yellow
(GNYE)
Functional earth
Brown
(BN)
Operating voltage
12 V version:
±12 Vdc ±20 %
24 V version:
±24 Vdc ±10 %
Control
The actuator extend or retract according to the polarity of the power
supply.
•
Retract: Connect blue to positive
•
Extend: Connect brown to positive
Blue