12
6. Type Label (Example)
Each drive component carries an identification plate giving the exact model, item number
and technical specifications (see following figure as an example).
The
MEGAMAT 4
is designated on the type plate as
MEGAMAT MEZ
.
13
Caution!
For Your Own Safety!
Shutdown in an emergency is achieved by pulling the mains plug out of the drive
controls!
The
mains plug
must therefore be accessible
at all times
when the system is in operation
to ensure it can be quickly
pulled out of the wall socket
in an emergency.
Movement of the drive takes place via a stroke pipe. Please bear this in mind when
designing your product:
Ÿ
After installing the
MEGAMAT 4
make sure that no shearing or trap/crush zones are
accessible from the outside.
In the Operating Instructions to be drawn up by yourselves, it is essential that you draw the
operator’s attention to the points mentioned here.
c)
Maintenance and Repairs
At regular intervals carry out the inspections. The recommended inspection period is:
6
months
In addition to the above, the following checks should be carried out at shorter intervals:
Ÿ
Regular visual checks
for damage of all kinds
Check the housing for
cracks
and
fractures
and the connection lead for signs of
pinching
and
shearing-off
. Also check the
strain relief
with
kink protection
, in
particular after each case of mechanical loading. Any
damaged connection
leads
of equipment must be replaced by
the manufacturer
or
persons qualified
to do so (see page 3) in order to exclude hazards.
Ÿ
Regular functional testing of the “quick release, GQR”
by actuating the
Bowden cable, as described on page 9, 10 and 11.
Ÿ
Regular visual checks of the “Quick Release, GQR”
through check for
completeness and correct seating of the seals to be found in the GQR.
Ÿ
Regular visual checks of the “Quick Release, GQR”
, to ensure that the function
is reliable and remains in the same constant quality, the actuator has to be
completely clean. We therefore recommend an optical check or eventually
cleaning including a final check of the quick release and the integration in the
service plan of the application.
Ÿ
Regular checks
of the Bowden cable of the "GQR quick release” at intervals to
ensure that it is functioning correctly. If necessary, re-adjust!
Ÿ
Check the limit switches by using the DewertOkin control unit to make the drive
travel to the end-of-travel positions.
MEGAMAT MEZ
Article type designation
Xxxxx
Article number
24-29V
Input voltage
Max. 3.50A
Current consumption
Duty cycle 2min ON / 18 min OFF
Intermittent operations: 2 minutes / 18 minutes
Max. Push Force
Push force
Max. Pull Force
Pull force
Prod.Date
Week / Year
Serial-No.
Serial number
IPX6
Protection category
Use in dry rooms only!
Follow all special disposal instructions!
Mark of CE conformity
MEGAMAT 4
03/2020
ID 59400 9.0
03/2020
ID 59400 9.0