background image

Phoenix International, Inc.

8711 West Port Avenue

Milwaukee, WI 53224  USA

Phone (414) 973-3400

Fax (414) 973-3210

www.phx-international.com

[email protected]

Phoenix International, Inc. warrants its products against defects in material and workman-
ship.  The company will, at its discretion, repair or replace any properly installed Phoenix
International manufactured product which fails under normal operating conditions within
one year from date of receipt. Contact the factory for return authorization before returning
the product to Phoenix International freight prepaid.  If our inspection confirms that the
product is defective under terms of this warranty, it will be repaired/ replaced and returned
freight prepaid.

This warranty applies only to Products sold by Phoenix International, Inc. and specifical-
ly excludes installation or de-installation labor, transportation, or equipment of another
manufacturer used in conjunction with Phoenix International products. No other warranty,
expressed or implied, exists beyond this warranty declaration.

Phoenix constantly strives to improve its products and therefore reserves the right to
change design, materials, and specifications without notice.

Your dryWIRE oven has adjustable shelving to accommodate different
diameter wire packaging.  Spools should be placed on the two center
rods for each shelf, so that the wire is stored in the middle of the oven.  

For optimal heating of the oven’s interior, spools should  be spaced
evenly throughout.  Make sure to leave some space between each
spool for air circulation to remove excess moisture.

To remove a rod from the shelving bracket:

1)  grasp rod and slide against one side of oven interior

2)  lift the other side up to the top of the shelving bracket notch

3) roll rod forward out of notch or pull forward until clear of notch open-
ing

4) rods can be arranged in a variety of ways (see Fig. 3), order pn#
1257100 for additional shelves

Note: the tolerances on the shelving rods are tight for safety reasons.

VII.

SHELVING ADJUSTMENT & SPOOL PLACEMENT

Caution

:  Packaging Materials

are Susceptible to Damage from
High Temperature - Contact Wire
Manufacturer for Temperature
Recommendations.

N5610275D-17

Summary of Contents for dryWIRE

Page 1: ...114 x 74 x 140cm 520 lbs 236 Kg 54 x 39 x 64 138 x 99 x 162cm N5610275D 1 Average Stabilized Temperature 70 F Ambient Temperature Operation on Direct Current will damage oven and void warranty A door mounting Thermometer Kit is available for use with all dryWIRE ovens new or old Easily installed in the field Order Part 1250300 Factory installation available with original order Order Part 1250301 T...

Page 2: ...r Beschreibung alle 50 60 Hz Temp Bereich Isolierung Kammer Größe Fassungsvermögen Nettogew Dimensionen Transportgew Dimensionen dryWIRE 1205430 240 480V AC 2500 Watt einphasig 38 bis 288 C 100 bis 550 F 14 C Regulierbarer Thermostatregler mit Anzeigelampe 5cm Glasfaser watte 89x53x119cm Bis zu 24 12 Spulen oder 16 16 Spulen 204kg 114 x 74 x 140cm 236kg 38 x 99 x 162cm Un nécessaire de thermomètre...

Page 3: ...of 230 F 300 F 110 C 149 C for a minimum of 6 to 12 hours Wire on plastic spools can not be rebaked because of plas tics inability to withstand high temperature Precise temper atures for wire storage and reconditioning should be obtained from the wire manufacturers technical department Another important factor in the storing and rebaking of flux cored wire is the lubricant on the outside of the wi...

Page 4: ...tué le tiroir Les fils bobinés les tiroirs en masonite ou les paniers métalliques sont recuits habituellement selon la gamme de température suivante 110 C 149 C 230 F 300 F pendant au moins 6 12 heures Les fils qui sont placés sur des tiroirs de plastique ne peuvent être recuits en raison de l incapacité du plastique à supporter des températures élevées Il importe d obtenir auprès du service techn...

Page 5: ... If necessary continue testing Warning Excess Heat At the maximum setting the actual tempera ture over the heating elements may reach 660oF 349 C Temperatures in excess of 550 F 288 C are not recom mended and may cause oven damage and or unacceptably high exterior surface temperatures Repair Spare Parts Enclosed with these instructions are wiring diagrams and a repair parts list for your oven For ...

Page 6: ... C 550 F n est pas recommandé et peut endommager le four ou augmenter les températures de la surface extérieure à un niveau inacceptable Réparation Pièces de rechange Ces directives sont accompagnées de schémas de câblage et d une liste de pièces de réparation pour votre four Dans le cas des opéra tions de soudage critiques qui requièrent une conservation continue nous suggérons de transporter tou...

Page 7: ...entire thermostat See Repair Parts Sheet 4 If thermostat operates satisfactorily check continuity of heating elements at bottom of oven Access through removable lower panels Failure of one element will pre vent oven operation on 480 volts If operating on 240 volts failure of one element will cause slow heating Remove oven from power source Replace BOTH elements Pairing of one new element with an o...

Page 8: ...nne pas remplacer tout le thermostat Consulter la Fiche sur les pièces de réparation 4 Si le thermostat fonctionne de façon satisfaisante vérifier la continu ité des éléments chauffants situés au centre du four Accès par les panneaux inférieurs amovibles La défaillance d un élément empêchera le fonctionnement du four à une tension de 480 volts Dans le cas d un four fonctionnant selon une tension d...

Page 9: ...80 VOLTS FOR CONNECTION TO A 240 VOLT POWER SOURCE REWIRE THE HEATING ELEMENT CONNECTIONS PER DIAGRAM SEE 240 VOLTS FOR CORD CONNECTION TO THE POWER SUPPLY ATTACH A 15 AMP PLUG OF CORRESPONDING VOLTAGE RATING TO THE CORD PROVIDED dryWIRE 480V WIRING DIAGRAM N5610275D 9 ...

Page 10: ... E Blanc F Fibre de verre blanc isolé G Rouge H Cordon SEO 14 4 I Manchon de fibre de verre J Thermostat K Lampe témoin L Élément chauffant ESTE HORNO SE ALAMBRÓ EN LA FÁBRICA PARA 480 VOLTIOS PARA CONECTARLO A UNA FUENTE DE ENERGÍA DE 240 VOLTIOS ALAMBRE NUEVA MENTE LAS CONEXIONES DEL ELEMENTO CALEFACTOR SEGÚN EL DIAGRAMA CONSULTE 240 VOLTIOS PARA CONECTAR EL CORDÓN A LA FUENTE DE ENERGÍA INSTALE...

Page 11: ...Numbers dryWIRE 240V 480V AC Thermostat Kit includes 7550280 Shelving Kit makes 1 shelf 2605700 Heating Element Kit includes 2751580 2751910 1257100 5110110 WHEN ORDERING SPECIFY PART NUMBER DESCRIPTION QUAN TITY AND THE FOLLOWING NAMEPLATE DATA TYPE MODEL NO AND VOLTAGE Note Always replace BOTH heating elements if one fails Two are required for each oven Replacement ele ments are sold in sets of ...

Page 12: ...ermostat 1 9 Poignée de thermostat 1 10 Boîtier de conduit 1 11 Couvercle de boîtier pr conduit 1 12 Joint statique par pi 14 13 Horiz bande de retenue pr joint 2 14 Vert bande de retenue pr joint 2 Nécessaire pour joint statique Nécessaire pour conduit 1257150 1257154 5110110 No pièces 240 V 480 V C A seul Qté Four Description N d art icle Nécessaire pour thermostat 7550280 Nécessaire pour rayon ...

Page 13: ... volt models One 1 door latch No 7550280 One 1 Gasket Kit No 1257154 V SUGGESTED SPARE PARTS dryWIRE OVENS For quantities of ovens exceeding 10 we suggest providing approximately 20 more of the above quantities of spares as sufficient for day to day operation For overseas operation we suggest a minimum of 30 more for spares N5610275D 13 ...

Page 14: ...in 1 Türriegel Nr 7550280 Ein 1 Dichtungszatz Nr 1257154 Pour un nombre de fours supérieur à 10 nous suggérons de fournir un nombre de pièces de rechange supérieur d environ 20 au nombre susmentionné pour une exploitation quotidienne Pour une exploitation à l étranger nous suggérons un nombre de pièces de rechange supérieur d au moins 30 Bei mehr als 10 Öfen empfehlen wir dass für den problemlosen...

Page 15: ...ure the hold downs will reach the oven leave a minimum of 4 75 from the back of the oven to the near est wall or obstacle see Fig 1 Using the openings found on the out side of both feet attach the hold downs found with the original pack aging to each of the ackermanns 2 To secure oven to the ground sink two ackermanns into the floor 35 1 apart leaving a minimum of 4 75 from the back of the oven to...

Page 16: ...extérieur des deux pieds fixer les mécanismes d ancrage fournis dans l emballage d origine à chaque ackermann 2 Pour fixer le four au plancher enfoncer deux ackermann espacés de 89 cm 35 1 po dans le plancher en laissant un espace minimal de 12 cm 4 75 po entre l arrière du four et le mur ou l obstacle à proximité consulter la fig 2 À l aide des fentes qui se trouvent à l arrière des deux pieds gl...

Page 17: ...pressed or implied exists beyond this warranty declaration Phoenix constantly strives to improve its products and therefore reserves the right to change design materials and specifications without notice Your dryWIRE oven has adjustable shelving to accommodate different diameter wire packaging Spools should be placed on the two center rods for each shelf so that the wire is stored in the middle of...

Page 18: ...ener Durchmesser gelagert werden können Die Spulen soll ten auf die zwei mittleren Stangen jedes Regals gelegt werden so dass das Draht nicht in der Mitte des Ofens gelagert wird Zur optimalen Beheizung des Ofeninneren müssen die Spulen gleich mäßig im Ofen verteilt sein Achten Sie darauf dass zwischen jeder Spule etwas Platz zur Luftzirkulation bleibt um übermäßige Feuchtigkeit zu entfernen Eine ...

Reviews: