Electrical connection
108366_en_01
PHOENIX CONTACT
4.1.1
Notes on using Y distributors and dummy plugs
Observe the following notes when connecting with Y distributors and the corresponding
dummy plugs:
–
Do not stick Y distributors directly on the connection of the safety switch.
–
Use suitable connecting cables to connect the Y distributor and the safety switch.
–
In order to prevent manipulation, install the Y distributors or cables out of reach of peo-
ple.
4.1.2
UL notes
Adhere to the following conditions for use according to cULus requirements
1
:
–
Use of a power supply with “for use in class 2 circuits” feature
–
Alternatively: electrically isolated power supply unit with a maximum off-load voltage of
30 V DC and a maximum limited current of 8 A
–
Use of a connecting cable that is listed under UL category code CYJV2 or CYJV
1
The devices have been checked according to the requirements of UL508 and CSA/ C22.2 no. 14 (protec-