PSR-CT
PHOENIX CONTACT
108366_en_01
3
Mounting
3.1
Positioning and distances
Figure 3-1
Transponder field of the sensor
Tip
: for safety switches with fixcode or unicode evaluation, perform teaching
before
mounting.
Observe the
orientation of the arrows
on the sensor and actuator in order to ensure the
following:
–
Permissible actuation position according to illustration (A, B, C, D)
–
Alignment of the sensor and actuator without center offset
See Section “Actuation positions and travel directions” on page 23.
The side lobes of the transponder field may influence the response behavior of the sensor
depending on the actuation position and travel direction.
•
In order to avoid influence of the side lobes, observe the specified
minimum dis-
tances
between sensor and actuator.
18
26
-26
-22
-18
Z
X
14
Y
-2
-6
-10
-26
-30
6
10
14
22
26
30
2
14
2
6
2
10
6
22
-14
-18
-22
10
18