System description
103503_en_03
PHOENIX CONTACT
2-3
Communication via the
PSR TBUS DIN rail
connector
The PSR-TRISAFE-S safety module is equipped with an interface for the PSR TBUS DIN
rail connector. The PSR DIN rail connector from Phoenix Contact can be used to connect
slave extension modules. Communication with these modules is then established
automatically via the connector on the PSR DIN rail connector. Safety-related cross-wiring
is not required (see also "Mounting the safety module" on page 3-13).
Figure 2-2
PSR TBUS DIN rail connector from Phoenix Contact
The maximum continuous current for extension modules supplied via the TBUS is 4 A.
INTERF
ACE-PSR
use only
PSR-TBUS
PSR-TRISAFE-S on
yellow
PSR
DIN rail connector
Standard
extension module
on
green
PSR DIN rail connector
(TBUS connection)
DIN rail
connector