![Philips VARI-Lite VL4000 User Manual Download Page 57](http://html.mh-extra.com/html/philips/vari-lite-vl4000/vari-lite-vl4000_user-manual_294550057.webp)
O
PERATION
: DMX O
PERATION
3
0 2 . 9 7 0 4 . 0 0 0 1 D
0 3 F e b r u a r y 2 0 1 5
39
Notes:
Default Values: *Denotes recommended console default settings.
48
Prism Diverge
0 - 255
0 - 100%
0
Controls spread of prism image from small (DMX 0) to wide (DMX 255).
Note : there are some diverge positions that will not be available due to
various lensing positions.
49
Frost
0 - 255
0 - 100%
0
Controls frost mechanism. Linear control from No Frost (DMX 0) to Full
Frost (DMX 255).
50
Strobe Speed
0 - 255
0 - 100%
0
Controls strobe rate from slowest (DMX 0) to fastest (DMX 255)
51
Strobe Control
0 - 255
0 - 100%
0
Control Channel for strobing functions.
0 - 5 = Open
6 - 10 = Closed
11 - 15 = Normal Strobe
16 - 20 = Random Strobe
21 - 25 = Random Sync
26 - 255 = Reserved Values
52
Focus Timing
0 - 255
0 - 100%
255
Allows for luminaire timing of pan and tilt mechanisms. Profile should
default to DMX 255 for smoothest console timing.
53
Optics Timing
0 - 255
0 - 100%
255
Adjustment of fixture timing to control lensing mechanisms. Profile
should default to DMX 255 for smoothest console timing.
54
Color Timing
0 - 255
0 - 100%
255
Allows for luminaire timing to control color mechanisms. Profile should
default to DMX 255 for smoothest console timing.
55
Beam Timing
0 - 255
0 - 100%
255
Allows for luminaire timing to control beam shaping mechanisms. Profile
should default to DMX 255 for smoothest console timing.
56
Gobo Timing
0 - 255
0 - 100%
255
Allows for luminaire timing to control gobo mechanisms. Profile should
default to DMX 255 for smoothest console timing.
57
Control
0 - 255
0 - 100%
0
To execute a command, the control channel must be set to idle (DMX 0)
then changed to a particular value and held for 3 seconds then restored
to DMX 0. Upon completion of this routine, the desired command will be
executed by the luminaire.
Used to strike/douse the lamp, set lamp levels, and other various func-
tions, as well as resetting the luminaire via the console. DMX values are:
0 - 5 = Idle (Default)
6 - 10 = Full Luminaire ReCal
(1)
(1) This command is also used to Wake fixture up from shutdown
11 - 15 = Lamp ON
16 - 20 = Lamp OFF
21 - 25 = Fixture Shutdown (for more information, see
“Fixture Shut-
down” on page 44
)
26 - 30 = Display - Menu ON
31 - 35 = Display - Menu OFF
36 - 40 = ReCal Position
41 - 45 = ReCal Color
46 - 50 = ReCal Gobo
51 - 55 = ReCal Beam
56 - 60 = ReCal Optics
61 - 65 = ReCal Dimmer/Strobe
66 - 70 = Reset Fixture to Defaults
71 - 75 = Full Luminaire Reboot
(2)
(2) This command will douse lamp and reset all processors in fixture,
then ReCal all parameters.
76 - 80 = Fixture Status On/Off
(3)
(3) This command will enable the display to
show fixture status for 5 min. After this time, displays will return
to default configuration. Repeating this command in less than 5
minutes will behave as a toggle.
81 - 85 = Standard Mode - Fixture operates at maximum output (Default)
86 - 90 = Studio Mode - Reduced output with lower fan settings
91 - 255 = Reserved Values
Table 3: VL4000 Spot Enhanced 16-Bit DMX Channel Mapping
DMX
Channel
Parameters
Range
(DMX)
Range
(%)
Default
Value*
Description / Operation
Summary of Contents for VARI-Lite VL4000
Page 1: ...VL4000 Spot Luminaire User s Manual ...
Page 13: ...FOREWORD 02 9704 0001 D 03 February 2015 xi ...
Page 14: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL xii 03 February 2015 02 9704 0001 D ...
Page 18: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 4 03 February 2015 02 9704 0001 D ...
Page 22: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 4 03 February 2015 02 9704 0001 D Notes ...
Page 46: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 28 03 February 2015 02 9704 0001 D Notes ...
Page 80: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 62 03 February 2015 02 9704 0001 D Notes ...
Page 112: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 94 03 February 2015 02 9704 0001 D Notes ...
Page 117: ......