Align Lamp For Maximum Beam Irradiance
After a new lamp is installed in the luminaire, it will be necessary to align the lamp to optimize the
beam.
WARNING:
Backcap and alignment screws will be HOT during lamp operation. Wear gloves and/or
use tools to prevent burns.
To align lamp:
Step
1. Set intensity to 100%.
Step
2. Position beam on a white wall at a distance of 10 to 20 feet.
Step
3. Using console or internal luminaire menu controls, set zoom to zero and focus to a hard
edge. Be sure that beam-size iris is completely opened.
Step
4. Using console or internal luminaire menu controls, insert Bricked Out gobo. This aids in
locating beam hot spot.
Step
5. Using three alignment screws (as indicated with Red Arrows in
Figure 2-5
) adjust hot spot
to center of beam.
Figure 2-5: Lamp Alignment Screws
NOTE: *Lamp Socket Cover removed for clarity. It is not necessary
to remove Lamp Socket Cover to align lamp.
Rear of Luminaire
Lamp (Beam)
Alignment Screws*
Do not loosen or use these
screws for adjustment.
Summary of Contents for VARI-Lite VL4000
Page 1: ...VL4000 Spot Luminaire User s Manual ...
Page 13: ...FOREWORD 02 9704 0001 D 03 February 2015 xi ...
Page 14: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL xii 03 February 2015 02 9704 0001 D ...
Page 18: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 4 03 February 2015 02 9704 0001 D ...
Page 22: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 4 03 February 2015 02 9704 0001 D Notes ...
Page 46: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 28 03 February 2015 02 9704 0001 D Notes ...
Page 80: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 62 03 February 2015 02 9704 0001 D Notes ...
Page 112: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 94 03 February 2015 02 9704 0001 D Notes ...
Page 117: ......