Troubleshooting
Error Messages
If a problem occurs during luminaire calibration, at the end of the calibration sequence the Menu
Display will cycle through any applicable error message(s), one at a time until the end of the list is
reached. To review the error messages again, it will be necessary to access them using the Status
function. Also, the VL4000 spot luminaire stores error messages in a log file within the luminaire. The
log file can be downloaded from the fixture’s USB port as described in
“USB Logging” on page 77
.
To access error messages:
Step
1. Press [ESC].
Step
2. Press [Up] / [Down] arrows until
Fixture
appears. Press [OK].
Step
3. Press [Up]/ [Down] arrows to access
Status
. Press [OK]. (Display will now scroll through
any error messages or display
OK
if no errors).
Table A-1: Error Messages
Display
Meaning
OK
No Errors Found - All Sensors Responded Properly
Pan Sensor
Pan Sensor (Encoder) Error
Tilt Sensor
Tilt Sensor (Encoder) Error
Dimmer Sensor
Dimmer Sensor Error
Cyan Sensor
Cyan Color Sensor Error
Yellow Sensor
Yellow Color Sensor Error
Magenta Sensor
Magenta Color Sensor Error
CTO Sensor
CTO Sensor Error
Color Whl1 Sensor
Color Wheel 1 Sensor Error
Color Whl2 Sensor
Color Wheel 2 Sensor Error
Gobo Whl1 Sensor
Rotating Gobo Wheel 1 Sensor Error
Gobo 1 Index Sensor
Rotating Gobo Wheel 1 Indexing Sensor Error
Gobo Whl2 Sensor
Rotating Gobo Wheel 2 Sensor Error
Gobo 2 Index Sensor
Rotating Gobo Wheel 2 Indexing Sensor Error
Animation Whl1 Sensor
Animation Wheel 1 Sensor Error
Animation 1 Index Sensor
Animation Wheel 1 Indexing Sensor Error
Animation Whl2 Sensor
Animation Wheel 2 Sensor Error
Animation 2 Index Sensor
Animation Wheel 2 Indexing Sensor Error
Prism Sensor
Prism Mechanism Sensor Error
Prism Rotate Sensor
Prism Rotating Sensor Error
Prism Diverge Sensor
Prism Diverge Sensor Error
Frost Sensor
Frost Mechanism Sensor Error
Frost Adjust Sensor
Frost Adjustment Sensor Error
Zoom Sensor
Zoom Assembly Sensor Error
Summary of Contents for VARI-Lite VL4000
Page 1: ...VL4000 Spot Luminaire User s Manual ...
Page 13: ...FOREWORD 02 9704 0001 D 03 February 2015 xi ...
Page 14: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL xii 03 February 2015 02 9704 0001 D ...
Page 18: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 4 03 February 2015 02 9704 0001 D ...
Page 22: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 4 03 February 2015 02 9704 0001 D Notes ...
Page 46: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 28 03 February 2015 02 9704 0001 D Notes ...
Page 80: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 62 03 February 2015 02 9704 0001 D Notes ...
Page 112: ...VARI LITE VL4000 SPOT LUMINAIRE USER S MANUAL 94 03 February 2015 02 9704 0001 D Notes ...
Page 117: ......