background image

PDS-60ca  Product 

Guide

4

Installation

PDS-60ca is a power/data supply designed for low-voltage linear DMX and Ethernet 

lighting installations. PDS-60ca provides power and data to up to 30 low-voltage luminaires 

from Philips Color Kinetics and delivers 60 watts of low-voltage output via two ports. It 

features a NEMA 4 (IP66) enclosure, and can be installed in dry, damp, and wet locations. It 

automatically accommodates input voltages ranging from 100 VAC to 240 VAC.

Owner/User Responsibilities

It is the responsibility of the contractor, installer, purchaser, owner, and user to install, 

maintain, and operate PDS-60ca in such a manner as to comply with all applicable codes, 

state and local laws, ordinances, and regulations. Consult with the appropriate electrical 

inspector to ensure compliance.

Plan the Installation

To streamline installation and ensure accurate configuration, start with a layout or a 

lighting design plan that shows the physical layout of the installation and identifies the 

locations of all lighting luminaires, power/data supplies, controllers, switches, and cables.

DMX, Ethernet, and Pre-Programmed Configurations

PDS-60ca DMX/Ethernet can be used in either DMX or Ethernet networks. Pre-

Programmed versions cannot receive controller data, but can send light show data to 

DMX or Ethernet power/data supplies using the pre-programmed device’s OUT port.
DMX is appropriate for relatively simple installations, or for installations in which 

groups of lights operate in unison (for example, for accent lighting, perimeter lighting, 

or cove lighting applications). Typical DMX installations with luminaires from Philips 

Color Kinetics use a controller such as iPlayer 3, a Controller Keypad for turning lights 

on and off and triggering light shows, and one or more PDS-60ca devices. PDS-60ca 

devices can be connected in series to deliver DMX data from a single controller to all 

connected lights. Note that the maximum for DMX data run lengths is 305 m (1,000 ft). 

iPlayer 3

Controller

PDS-60ca 7.5V 

DMX/Ethernet

iColor Flex MX gen2

Because it is not subject to the DMX addressing limitations, Ethernet is the preferred 

environment for large-scale, color-changing light shows and video displays, both of which 

require large numbers of unique addresses.
Typical Ethernet installations with LED lighting luminaires from Philips Color Kinetics 

use an Ethernet switch, an Ethernet controller (such as Light System Manager, 

ColorDial Pro or Video System Manager Pro), one or more Ethernet Controller 

Keypads (for light show triggering), and one or more PDS-60ca devices. For additional 

devices in a network, use additional Ethernet switch ports.
In an Ethernet environment, each Philips Color Kinetics power/data supply has a unique 

IP address. Each luminaire connected to the device is automatically assigned unique 

identifiers that controllers use to identify and manage each luminaire.

Maximum data cable lengths are 100 m (328 ft) between Ethernet devices without a 

repeater.

E

 

Refer to the PDS-60ca Installation 

Instructions for specific warning and caution 

statements.

Power/ 

Data Supply

Power/ 

Data Supply

Controller

100 m (328 ft) Max

Controller

305 m (1,000 ft) Max

DMX maximum data run length

Pre-Programmed Installation

PDS-60ca 7.5 V 

Pre-programmed

(master unit)

iColor Flex MX gen2

PDS-60ca 7.5 V 

DMX/Ethernet

(all other units)

Summary of Contents for PDS-60ca

Page 1: ...PDS 60ca Power data supply for indoor and outdoor applications ...

Page 2: ...nal power data supplies A downstream power data supply does not have to be a PDS 60ca but can be any DMX or Ethernet based power data supply Instead of attaching luminaires to a Pre Programmed PDS 60ca you could use it as an outdoor rated light show controller for DMX or Ethernet based power data supplies and their luminaires Compatible Luminaires Device Luminaire Max Quantity Per Device PDS 60ca ...

Page 3: ...nput and output connectors Power Output 2 4 pin output receptacles Power Input Line neutral ground cable flying leads Temperature Ranges 10 to 40 C 14 to 104 F Operating 10 to 50 C 14 to 122 F Startup 40 to 80 C 40 to 176 F Storage Humidity 0 to 95 non condensing Cooling Convection Heat Dissipation 25 of total power input at maximum load Data Input Source PDS 60ca 7 5 V DMX Ethernet Philips full r...

Page 4: ...applications Typical DMX installations with luminaires from Philips Color Kinetics use a controller such as iPlayer 3 a Controller Keypad for turning lights on and off and triggering light shows and one or more PDS 60ca devices PDS 60ca devices can be connected in series to deliver DMX data from a single controller to all connected lights Note that the maximum for DMX data run lengths is 305 m 1 0...

Page 5: ...tions as required Standard 3 31 mm2 12 AWG stranded wire is recommended Three wire connectors CAT 5e or better data cable as required The included black magnetic EMI suppression core for the power cable The included two white magnetic EMI suppression cores for iColor Flex eW Flex strands or luminaire leader cables Power screwdriver for mounting Four screws suitable for the mounting surface Phillip...

Page 6: ... cord is doubled into the suppression core Be sure the cord is securely in the core s middle Snap the core shut around the doubled cord Attach a white suppression core to the luminaire strand or leader cable attached to port 1 Near the connection to the power data supply coil the strand or cable into a small loop Place the section of the loop where the cord is doubled into the suppression core Be ...

Page 7: ...cted PDS 60ca automatically switches to the appropriate mode Since pre programmed devices do not accept controller data you will not be able to use the DMX IN port on these devices However you can use the device s DMX OUT port to link to downstream power data supplies which can receive light show data DMX 1 Using an RJ45 connector cable connect your controller s DMX output port to the DMX IN port ...

Page 8: ...ection for instructions on how to link other power data supplies via DMX OUT ports To achieve the effects you want you can use the controls inside the device which consists of a toggle switch and three buttons Once you have set the mode speed and options for effects using the control button PDS 60ca stores settings and records them even after you have cycled the power on the device To display effe...

Page 9: ...gs Cycles through four width settings 2 White Chasing Comet Displays a band of light that appears to move across a dark background Cycles through five distinct comet width settings 3 Dark Chasing Comet Displays a dark band that appears to move across a light background Cycles through five distinct comet width settings 4 Random Sparkle Produces a series of light flashes at regular intervals on rando...

Page 10: ... discover all PDS 60ca devices in an installation using QuickPlay Pro which automatically determines how many luminaires are connected to each output port and addresses them Light System Manager and Video System Manager Pro Ethernet lighting controllers from Philips Color Kinetics also automatically discover and address all connected luminaires Pre programmed PDS 60ca devices cannot receive input ...

Page 11: ... or damp location seal with RTV silicone Installing in Damp or Wet Locations When installing in damp or wet locations seal all junction boxes power supplies and other devices with electronics grade RTV silicone sealant so that water or moisture cannot enter or accumulate in any wiring compartments cables luminaires or other electrical parts You must use suitable outdoor rated junction boxes when i...

Page 12: ...ng in a wet or damp location seal with RTV silicone Device Replacement Fuse PDS 60ca 7 5 V 2 5 A 5 x 20 slow blow fuses PDS 60ca 24 V 2 4 A 5 x 20 slow blow fuses Fuse OUT 1 OUT 2 DMX IN DMX OUT ETHERNET Power Indicators Copyright 2018 Philips Lighting Holding B V All rights reserved Chromacore Chromasic CK the CK logo Color Kinetics the Color Kinetics logo ColorBlast ColorBlaze ColorBurst ColorGr...

Reviews: