22
4. Power supply
MG5.1E
4.3 Full power supply
Personal notes
The Power Factor Correction, Standby, and Full Power circuits
are all located on the Power Supply panel. (Figure 4-8) The
Standby supply feeds the 5 volt standby supply to the Small
Signal panel via Pin 5 of connector 121 0. The Standby voltage
is present whenever power is applied to the set and the Mains
switch is On. The On/Off Command from the Small Signal panel
is fed to the Power Supply on Pin 8 of connector 121 0. This Pin
will measure 5 volts when the set is in the standby mode and 0
volts when the set is turned On. The +33, +15, +8.6, and +5.2
volt supplies to the Small Signal panel are developed after the
set is turned On.
The +130, +15, +8.6, -7.7, and 5 volt standby voltages are fed
to the Interface panel on connector 1202. The 50/60 Hz signal
is a sync signal from the AC power mains which is used to
provide sync to the clock circuit on the Small Signal panel.
350 volts from the Power Factor Correction circuit is fed to the
Audio Amplifier on connector 1203. The Control line on Pin 4 of
1203 provides the operating voltage for the switching power
supply on the Audio Amplifier panel. This Control voltage is
switched Off when the set is in the Standby mode.
Connector 1276 routes power to the Convergence panel while
connectors 1212 and 1211 feeds power to the Scan High
Voltage panel.