6. SMALL SIGNAL PANEL
67
6.10 Protection structure
Figure 6-27
CL 86532047_040.eps
140798
7556
Vbatt
Main
supply
FFS
220V
+Vs
+7V7
2700
L
R
S
C
-Vs
-7V7
1002
7000
7001
7550
6570
DCprot (76)
µ
P
6571
5VST-by
7762
AUDIO
7761
7796
8V6
5V2
+Vs (16V)
-
S DC PROT
Service mode via 0356 connector SSP.
Via the service plug O356 on the SSP (short circuit 1-2: Service
Default Mode; short circuit 2-3: Service Alignment Mode) ALL
software controlled protections are de-activated. (featurebox-
protection, 5V2, 8V6, DC-prot, BC-prot, VFB, HFB, LDP).
Therefore it is only allowed for Service people to enter this
mode. You must be aware what you are doing. For recognition:
IF PROTECTION IS OVERRULED THE LED WILL BLINK
ORANGE IN STEAD OF RED.
Real Hardware-protections as DC-prot, HFB and LDP will
always monitor the set-situation. So also with a non-working
micro controller these protections are functional. The
hardware-protections VFB and BC-prot stay de-activated in
service-mode.
Stepwise startup explanation
Via ComPair the stepwise startup can be realised. This is very
helpful when a protection is activated.
State
Description mode
Display leds
Errorcode
possible
0
Low Power Standby/uC
in Stby
Red on
None
1
High Power Standby/
set in Stby
Red 0.5Hz
None
2
Supply on. Protections
5V2, 8V6, DC-Prot acti-
vated.
Orange/Green 0.25
Hz
67,68,76
3
ICs initialized. (Sound).
Protection 3V3 activat-
ed
Orange/Green 0.5
Hz
plus 77
4
EHT startup. No black-
current stabilisation.
Protections VFB, HFB,
LDP, BC-prot activated
(blanked picture)
Orange/Green 2 Hz
plus
70,71,73,74
5
TV operates, un-
blanked picture
Orange/Green 10 Hz