68
6. SMALL SIGNAL PANEL
MG5.1E
6.10 Protection structure
Personal notes
Stepwise shutdown explanation
In the stepwise shutdown mode, state 2 is skipped. (ICs can not
be de-initialised).
Note:
When set is in stepwise-mode and due to stepping-up a
protection is activated, the set really will go into protection
(blinking red led). The set will not leave the stepwise-mode
however. By stepping up the set can be activated again, until
state X, where protection was activated. At state (X-1)
diagnostic measurements can be performed.
Mode
/ State
Description mode
Display leds (Note *) Prot. de-acti-
vated
5
TV operates, unblanked
picture
Orange/Green 10
Hz
None
4
No blackcurrent stabili-
sation. All protections
are enabled
Orange/Green 2 Hz None
3
ICs stay initialised.
(Sound). All protections
are off
Orange/Green 0.5
Hz
74,73,71,70
1
High Power Standby/
set in Stby
Red 0.5Hz
77,76,68,67
0
Low Power Standby/uC
in Stby
Red on
None