3. Technical Specifications
3.1
Power Supply
3.1.1 Type
and
versions
Build-inSMPS will be used for all models and stroke versions.
All using figure '8' socket, will cater for all versions:
Versions
Region/Country SMPS
Detachable mains cords
12 / 05
EUROPE / UK
1) 100 ~240Vac nom. (wide
range from 90V~264Vac limit)
used in all versions except
India.
Frequency: 47~63Hz.
EU (/12) round 2-pin & UK (/05) 3-pin
37 NAFTA
UL flat pin (non-polarized)
n
i
p
-
2
d
n
u
o
r
d
e
i
f
i
t
r
e
c
O
R
T
E
M
N
I
M
A
T
A
L
5
5
n
i
p
-
2
d
n
u
o
r
U
E
C
A
P
A
8
9
94 India
2) 100 ~310Vac limit (India
compatible with up cost) used
only for India.
Frequency: 47~63Hz.
EU (/12) round 2-pin
All requirements per defined for each country should be met with sufficient testing.
3.1.2
Surge Immunity (Lightning Test)
The product shall withstand mains interference’s of:
Differential mode:
2kV/2 ohm criteria C for Europe.
6kV/12 ohm criteria C for NAFTA.
Parameters:
Bi-wave
Open
circuit
voltage:
2/50us
Short
circuit
current:
8/20us
From +/1kV to +/-2kV (for Europe) or +/-6kV (for Nafta) in steps of 1kV.
10 shots per combination.
One shot per minute.
Serial
impedance:
2
Ohm
for Europe, 12Ohm for Nafta.
Polarity and phase: Positive (phase 90º) & Negative (phase 270º)
Technical Specification and Connection Facilities
1-6
Summary of Contents for MCD2010/12/93
Page 26: ...8 2 Fig D4 Cabinet Disassembly Instructions ...
Page 33: ...Display Board Layout Diagram 12 3 12 3 ...
Page 35: ...Power Board Layout Diagram 12 5 12 5 ...
Page 42: ...Decoder Board Layout Diagram 12 12 12 12 ...
Page 44: ...Revision List Revision List Version 1 0 Initial Release 14 1 ...