EN 88
3139 785 32804
Firmware Upgrading & Diagnostic Software
5.
Nucleus Name
DS_HDD_SetPower
Nucleus Number
2112
Description
Set the power of the HDD On or Off
Technical
-
Get user input
-
Set the IDE1_POWER PIO line to the desired value
Execution Time
Less than 1 second.
User Input
1 parameter:
"ON" , enables the power of the HDD
"OFF" , turn off the power of the HDD
Error
Number
Description
211200
Setting the HDD power mode succeeded
211201
Setting the HDD power mode failed
211202
Invalid user input
Note
All other HDD nuclei will not work until DS_HDD_Reset is executed
Example
DS:> 2112 off
211200:
Test OK @
Nucleus Name
DS_HDD_ValidateBootSegmentHeader
Nucleus Number
2113
Description
Validates the Boot Segment Header in the HDD.
Technical
-
Initializes the HDD interface.
-
Reads 8 bytes from LBA 0x8001
-
Compares these 8 bytes with 0x42,0x4F,0x4F,0x54,0x2D,0x48,0x44,0x4D
-
If identical, returns pass. Else Hard Disk Boot Segment Header is corrupt.
Execution Time
Less than 1 second.
User Input
None.
Error
Number
Description
211300
Validation of Hard Disk Boot Segment Header passed.
211301
Hard Disk Boot Segment Header corrupt or does not match
expected values.
211302
HDD init failed.
211303
Starting HDD failed.
211304
Reading from HDD failed.
Example
DS:> 2113
211300:
Test OK @