Safety Precautions

CAUTION

RISK OF ELECTRIC

SHOCK. DO NOT OPEN! 

CAUTION: TO REDUCE THE RISK OF ELECTRICAL
SHOCK, DO NOT OPEN COVERS. NO USER
SERVICEABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.

This label may appear on the bottom of the unit due to space
limitations.

The lightning flash with an arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated "dangerous voltage" within the
product's enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is
intended to alert the user to presence of important operating
and maintenance (servicing) instructions in the literature
accompanying the appliance.

Warning
To prevent fire or shock hazard, do not expose units not
specifically designed for outdoor use to rain or moisture.

Attention: Installation should be performed by qualified
service personnel only in accordance with the National
Electrical Code or applicable local codes.

Power Disconnect. Units with or without ON-OFF switches
have power supplied to the unit whenever the power cord is
inserted into the power source; however, the unit is
operational only when the ON-OFF switch is in the ON
position. The power cord is the main power disconnect for all
units.

External Power Supplies

Use only the Recommended Power Supplies.  Power
supplies must comply with the requirements of the latest
version of IEC 65/VDE 0860. Substitutions may damage the
unit or cause a fire or shock hazard.

24 VAC Units

Do Not Exceed 30 VAC Input. Voltage applied to the unit's power
input should not exceed 30 VAC. Normal input voltage is 24 VAC. User
supplied wiring from 24 VAC supply to unit must be in compliance with
electrical codes (Class 2 power levels). Do not ground 24 VAC supply
at power supply terminals or at unit's power supply terminals.

220-240 V, 50 Hz Power Cords

220-240 V, 50 Hz power cords, input and output, must comply
with the latest versions of IEC Publication 227 or IEC
Publication 245.

Securite

RISQUE DE CHOC ELECTRIQUE.

NE PAS OUVRIR. 

ATTENTION

Danger: Pour éviter tout risque d'électrocution, ne pas
ouvrir le boîtier. Il n'y a pas de pièces remplaçables à
l'intérieur. Pour toute révision, s'adresser à un technicien
spécialisé.

Cet étiquette peut apparaître en dessous de l'appareil dû aux
limitations d''espace.

L'éclair fléché dans un triangle équilatéral avertit l'utilisateur
de la présence d'une haute tension non isolée à l'intérieur de
l'appareil. Elle peut être d'une magnitude suffisante pour
constituer un risque d'électrocution.

Le point d'exclamation à l'intérieur d'un triangle équilatéral
avertit l'utilisateur de la présence d'instructions importantes
d'utilisation et de maintenance dans la documentation
accompagnant l'appareil.

Attention
Pour éviter un incendie ou une électrocution, ne pas exposer
les appareils qui ne sont pas conçus spécifiquement pour
usage extérieur à la pluie ou à l'humidité.

Attention: L'installation doit être effectuée uniquement par du
personnel de service qualifié conformément à la
réglementation du Code Electrique National ou à la
réglementation locale.

Disjonction de l'alimentation. Les appareils avec ou sans
commutateurs ON-OFF sont alimentés à chaque fois que le
cordon d'alimentation est branché à la source d'alimentation;
toutefois, les appareils disposant de commutateurs ON-OFF
ne fonctionnnent que lorsque le commutateur ON-OFF est sur
la position ON. Le cordon d'alimentation est la disjonction
d'alimentation principale pour tous les appareils.

Sources d'alimentation extérieures

Utiliser uniquement les sources d'alimentation
recommandées. 

Les sources d'alimentation doivent être

conformes aux réglementations de la dernière version IEC
65/VDE 0860. Toute modification peut endommager l'appareil
ou provoquer un incendie ou un choc électrique.

Appareils 24 VCA

Ne pas excéder 30 VCA. La tension appliquée à l'entrée d'alimentation
de l'appareil ne devrait pas excéder 30 VCA. Toute installation
électrique fournissant du 24 Volts courant alternatif doit être conforme
aux codes électriques. (Niveaux d'alimentation de la Classe 2). Ne pas
brancher une prise de terre sur les bornes d'alimentation 24 Volts ou
aux bornes d'alimentation de l'appareil.

Les cordons secteur 220-240 V, 50 Hz

Les cordons secteur 220-240 V, 50 Hz, entrée et sortie,
doivent êtro conformes aux versions les plus récentes de la
publication 227 de la C.I.E. ou à la publication 245 de la C.I.E.

Summary of Contents for AutoDome TC700 Series

Page 1: ...AutoDome System TC700 Series Camera Lens Pan Tilt and Receiver Driver Modules User s Manual ...

Page 2: ...objects of any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the unit 16 Servicing Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 17 Da...

Page 3: ... d électrocution ne pas ouvrir le boîtier Il n y a pas de pièces remplaçables à l intérieur Pour toute révision s adresser à un technicien spécialisé Cet étiquette peut apparaître en dessous de l appareil dû aux limitations d espace L éclair fléché dans un triangle équilatéral avertit l utilisateur de la présence d une haute tension non isolée à l intérieur de l appareil Elle peut être d une magni...

Page 4: ...Favor No Abrir La Cubierta Este Equipo No Consta De Piezas O Partes Que Requieren Servicio O Mantenimiento Para Reparaciones Favor Referirse A Un Técnico Calificado Debido a limitaciones de espacio esta etiqueta puede aparecer en la parte inferior de la unidad El símbolo representado por un relámpago con punta de flecha dentro de un triángulo equilátero se muestra con el objetivo de alertar al usu...

Page 5: ...giant biphase TC750 9 2 EIA RS 170 8 7 to 87 mm RS 232 TC750X 4 1 CCIR 4 to 40 mm Allegiant biphase TC750X 4 2 CCIR 4 to 40 mm RS 232 TC750X 6 1 CCIR 5 8 to 58 mm Allegiant biphase TC750X 6 2 CCIR 5 8 to 58 mm RS 232 TC750X 9 1 CCIR 8 7 to 87 mm Allegiant biphase TC750X 9 2 CCIR 8 7 to 87 mm RS 232 Color Models Model No Color System Lens 1 Receiver TC770 4 1 NTSC 4 to 40 mm Allegiant biphase TC770...

Page 6: ...n the Installation and Operating Instructions supplied with the particular Backbox Module ordered CAUTION Do not handle the unit by the circuit board because this may result in physical damage to the unit OPERATION Camera Control These units as shipped are factory adjusted as described below Line lock mode enabled with zero degree phase delay AGC on Backlight compensation off Electronic shutter of...

Page 7: ...ttings are stored with pre position scenes Pan position Tilt position Zoom position Focus mode AUTO MANUAL Focus position for MANUAL mode Iris mode AUTO MANUAL Iris ALC LEVEL for AUTO mode or position for MANUAL mode White Balance mode AUTO MANUAL color cameras only Red content and Blue content for MANUAL mode color cameras only Shutter mode ON OFF Shutter setting for ON mode Backlight compensatio...

Page 8: ... 2 3 s Off Off Off 4 On Off Off 6 Off On Off 10 On On Off 15 Off Off On 20 On Off On 30 Off On On 45 On On On 60 If the auto speed feature is enabled see DIP switch S2005 4 these DIP switches apply only to the tilt speed S2005 4 This switch controls the Auto speed feature When on auto speed is always enabled and control by AUX 16 is ignored see Auto Speed AUX 16 under SETUP MAINTENANCE in TC700 Se...

Page 9: ...ating point If the field of view contains large brightly lit background areas and a small dimly lit foreground object the camera AGC may select an operating point that does not allow for adequate viewing of the foreground object The AutoDome series cameras have a fixed zone backlight compensation mode to alleviate this problem With backlight compensation turned on the camera determines its AGC ope...

Page 10: ...automatic white balancing is now disabled Turning on the manual white balance disables the automatic white balance There are 107 steps of adjustment for changing either the red or blue content of the picture Manual White Balance Increase Red Issuing this command increases the red content of the picture by one step AUX 31 On Manual White Balance Decrease Red Issuing this command decreases the red c...

Page 11: ...IONS Tilt Motor Site Address Thumbwheel DIP Switches Remove Foam Prior To Operation S9407002AE Connector Remove Screw Shipping Bracket Prior to Operation TC700 Series Camera Lens Pan Tilt and Receiver Driver Module ...

Page 12: ...hilips Communication Security Systems Inc 1004 New Holland Avenue Lancaster PA 17601 5606 USA Tel 1 717 295 6123 Fax 1 717 295 6097 Philips Communication Security Systems Inc 750 Vista Blvd Suite 403 Sparks NV 89434 USA Tel 1 702 331 4155 Fax 1 702 331 2306 Philips Communication Security Systems Inc Access Control Hardware 7041 Orchard Dearborn MI 48126 1781 USA Tel 1 313 846 2623 Fax 1 313 846 35...