THIS ADJUSTMENT DESCRIPTION CONTAINS INSTRUCTIONS FOR ADJUSTING THE CHANGER when it
does not correctly function as a result of rough handling of the transport and operation of the device,
or after prolonged and frequent use.
When adjusting, the device must be set up in normal operating position [horizontal]. if these
instructions can not be used to achieve the desired result, or if the error that occurs is not mentioned
below, the more detailed instructions stated under
Chapter IX
of the sevice documentation must be
consulted.
I
When the device is started, the turntable starts rotating, but the
mechanism does not start
.
The curved end of the starter
spring [1
] does not move the driver into the "outer" position. As a result,
the nose
[3] -VI
is not brought against the main axis
[4] -VI
. Bend the spring slightly, but so that it
remains parallel with the control disc When the start handle is forwarded, the contact point of the cam
and the starter spring must be in
A [see fig.]